词条 | Continuity of Care Record |
释义 |
| title = Continuity of Care Record | long_name = ASTM E2369 - 12: Standard Specification for Continuity of Care Record (CCR) | image = | caption = | status = | year_started = | first_published = | version = | version_date = | preview = | preview_date = | organization = ASTM International | committee = E31.25 | editors = | authors = | base_standards = XML | related_standards = | abbreviation = CCR | domain = Electronic health records | license = Proprietary | website = {{URL|https://www.astm.org/Standards/E2369.htm}} }}Continuity of Care Record (CCR)[1] is a health record standard specification developed jointly by ASTM International, the Massachusetts Medical Society (MMS), the Healthcare Information and Management Systems Society (HIMSS), the American Academy of Family Physicians (AAFP), the American Academy of Pediatrics (AAP), and other health informatics vendors.[1] Background and scopeThe CCR was generated by health care practitioners based on their views of the data they may want to share in any given situation.[2]{{Failed verification|date=March 2013}} The CCR document is used to allow timely and focused transmission of information to other health professionals involved in the patient's care.[2] The CCR aims to increase the role of the patient in managing their health and reduce error while improving continuity of patient care.[3] The CCR standard is a patient health summary standard. It is a way to create flexible documents that contain the most relevant and timely core health information about a patient, and to send these electronically from one caregiver to another. The CCR's intent is also to create a standard of health information transportability when a patient is transferred or referred, or is seen by another healthcare professional.[4] Development{{Unreferenced section|date=August 2017}}The CCR is a unique development effort via a syndicate of the following sponsors:
ContentThe CCR data set contains a summary of the patient's health status including problems, medications, allergies, and basic information about health insurance, care documentation, and the patient's care plan.[4] These represent a "snapshot" of a patient's health data that can be useful or possibly lifesaving, if available at the time of clinical encounter.[2] The ASTM CCR standard's purpose is to permit easy creation by a physician using an electronic health record (EHR) system at the end of an encounter.[2] More specifically within the CCR, there are mandated core elements in 6 sections.[4] These 6 sections are:
CCR standard and structureBecause it is expressed in the standard data interchange language known as XML, a CCR can potentially be created, read, and interpreted by any EHR or EMR software application. A CCR can also be exported to other formats, such as PDF or Office Open XML (Microsoft Word 2007 format).[4] The Continuity of Care Document (CCD) is an HL7 CDA implementation of the Continuity of Care Record (CCR). A CCR document can generally be converted into CCD using Extensible Stylesheet Language Transformations (XSLT), but it is not always possible to perform the inverse transformation, since some CCD features are not supported in CCR.[5] HITSP provides reference information that demonstrates how CCD and CCR (as HITSP C32) are embedded in CDA.[6] Although the CCR and CCD standards could continue to coexist, with CCR providing for basic information requests and CCD servicing more detailed requests, the newer CCD standard might eventually completely supplant CCR.[7] TechnologyAs mentioned, the CCR standard uses eXtensible Markup Language (XML) as it is aimed at being technology neutral to allow for maximum applicability.[4] This specified XML coding provides flexibility that will allow users to formulate, transfer, and view the CCR in a number of ways, for example, in a browser, in a Health Level 7 (HL7) message, in a secure email, as a PDF file, as an HTML file, or as a word document. This is aimed at producing flexible expression of structured data in avenues such as electronic health record (EHR) systems.[8] In terms of the CCR's transportability, secure carriage and transmission of the electronic file can occur via physical transport media, for example on a USB thumb drive, tablet or phone, CD ROM, or smart card, and in an electronic sense, secure transmission can occur via a network line, or the Internet.[8] See also
References1. ^1 {{cite techreport |title=Standard Specification for Continuity of Care Record (CCR) |number=ASTM E2369 - 12 |type=Active standard |institution=ASTM International |date=2012 |url=https://www.astm.org/Standards/E2369.htm |doi=10.1520/E2369-12 }} 2. ^1 2 3 {{cite journal|first1=Jeffrey M.|last1=Ferranti|first2=R. Clayton|last2=Musser|first3=Kensaku|last3=Kawamoto|first4=W. Ed|last4=Hammond|title=The Clinical Document Architecture and the Continuity of Care Record: A Critical Analysis|journal=Journal of the American Medical Informatics Association|date=May–June 2006|volume=13|issue=3|pages=245–252|doi=10.1197/jamia.M1963|doi-access=free|pmid=16501180|pmc=1513652}} 3. ^{{cite journal |last1=Kibbe |first1=David C. |last2=Phillips |first2=Robert L., Jr. |last3=Green |first3=Larry A. |date=1 October 2004 |title=The Continuity of Care Record |journal=American Family Physician |volume=70 |issue=7 |pages=1. 220, 1222-3 |department=Editorial |pmid=15508532 |url=http://www.aafp.org/afp/2004/1001/p1220.html }} 4. ^1 2 3 4 {{cite report |publisher=American Society for Testing and Materials |date=2013 |title=Continuity of Care Record:The Concept Paper of the CCR }} 5. ^{{cite book |first1=Fred |last1=Trotter |first2=David |last2=Uhlman |date=2011 |chapter=Chapter 10. Interoperability |chapter-url=https://web.archive.org/web/20110914043045/http://ofps.oreilly.com/titles/9781449305024/meaningful_use_interoperability.html |title=Getting to Meaningful Use and Beyond |publisher=O'Reilly Media |isbn=978-1-4493-0502-4 |url=http://ofps.oreilly.com/titles/9781449305024/index.html |archive-date=3 September 2011 |archive-url=https://web.archive.org/web/20110903031803/http://ofps.oreilly.com:80/titles/9781449305024/index.html }} 6. ^{{cite web |date=December 2009 |title=HITSP 09 N 451 – Comparison of CCR/CCD, CDA Documents and HITSP Products |website=ANSI Public Document Library |url=http://publicaa.ansi.org/sites/apdl/hitspadmin/Matrices/HITSP_09_N_451.pdf |format=PDF |accessdate=2011-08-06 |deadurl=yes |archiveurl=https://web.archive.org/web/20111001055244/http://publicaa.ansi.org/sites/apdl/hitspadmin/Matrices/HITSP_09_N_451.pdf |archivedate=2011-10-01 |df= }} 7. ^{{cite web |first=David C. |last=Kibbe |date=19 June 2008 |url=http://e-caremanagement.com/untangling-the-electronic-health-data-exchange/|title=Untangling the Electronic Health Data Exchange|website=e-CareManagement Blog |publisher=Better Health Technologies, LLC }} 8. ^1 {{cite web |first=David C. |last=Kibbe |date=10 August 2006 |title=An Overview of the ASTM Continuity of Care Record (CCR) |website=NCHICA |publisher=North Carolina Healthcare Information and Communications Alliance, Inc. |url=http://www.nchica.org/Past/06/presentations/Kibbe.pdf |format=PDF |accessdate=2013-06-09 |deadurl=yes |archiveurl=https://web.archive.org/web/20130114220532/http://www.nchica.org/Past/06/presentations/Kibbe.pdf |archivedate=2013-01-14 |df= }} External links
3 : Industry-specific XML-based standards|Medical records|Standards for electronic health records |