}} A CO-oximeter is a device that measures the oxygen carrying state of hemoglobin in a blood specimen, including oxygen-carrying hemoglobin (O2Hb), non-oxygen-carrying but normal hemoglobin (HHb) (formerly, but incorrectly, referred to as 'reduced' hemoglobin), as well as the dyshemoglobins such as carboxyhemoglobin (COHb) and methemoglobin (MetHb). The use of 'CO' rather than 'Co' or 'co' is more appropriate since this designation represents a device that measures carbon monoxide (CO) bound to hemoglobin, as distinguished from simple oximetry which measures hemoglobin bound to molecular oxygen—O2Hb—or hemoglobin capable of binding to molecular oxygen—HHb. Simpler oximeters may report oxygen saturation alone, i.e. the ratio of oxyhemoglobin to total 'bindable' hemoglobin (i.e. oxyhemoglobin + deoxyhemoglobin-HHb). CO-oximetry is useful in defining the causes for hypoxemia, or hypoxia, (oxygen deficiency at the tissue level). How it worksA CO-oximeter measures the absorption of light passing through blood from few as two or three wavelengths of light to several dozens of wavelengths, in order to distinguish oxyhemoglobin, and deoxyhemoglobin (formerly called 'reduced' hemoglobin), and thus determine the oxyhemoglobin saturation ( UsageWhen a patient presents with carbon monoxide poisoning (CO) or other non-respiratory hypoxic symptoms, most current CO-oximeters will detect the relative levels of each hemoglobin fraction (oxyhemoglobin and dyshemoglobins) and likely the oxyhemoglobin saturation. For any system making these measurements it is critical that the device clearly distinguish between Oxygen Saturation' and Fractional Oxyhemoglobin" . The issue here is the careless use of saturation vs. fractional oxyhemoglobin, which both measure the same entity -oxyhemoglobin- but the oxygen saturation uses as its base only the hemoglobin available for binding, while the fractional oxyhemoglobin uses the total hemoglobin in the sample as its base. In normal subjects the values are nearly identical-thus leading to terminologic and possibly clinical confusion. A simple oximeter measuring only oxygen derivatives, may report a normal saturation or even a hyperoxic state if oxygen gas has been administered when in fact there is serious compromise of oxygen carrying ability of the hemoglobin present. See also
References1. ^{{cite journal |vauthors=Rodkey FL, Hill TA, Pitts LL, Robertson RF |title=Spectrophotometric measurement of carboxyhemoglobin and methemoglobin in blood |journal=Clinical Chemistry |volume=25 |issue=8 |pages=1388–93 |date=August 1979 |pmid=455674 |doi= |url=http://www.clinchem.org/cgi/pmidlookup?view=long&pmid=455674 |accessdate=2009-07-17}} 2. ^{{cite journal |vauthors=Rees PJ, Chilvers C, Clark TJ |title=Evaluation of methods used to estimate inhaled dose of carbon monoxide |journal=Thorax |volume=35 |issue=1 |pages=47–51 |date=January 1980 |pmid=7361284 |pmc=471219 |doi= 10.1136/thx.35.1.47|url=http://thorax.bmj.com/cgi/pmidlookup?view=long&pmid=7361284 |accessdate=2009-07-17}} 3. ^{{cite journal |vauthors=Coulange M, Barthelemy A, Hug F, Thierry AL, De Haro L |title=Reliability of new pulse CO-oximeter in victims of carbon monoxide poisoning |journal=Undersea & Hyperbaric Medicine |volume=35 |issue=2 |pages=107–11 |year=2008 |pmid=18500075 |doi= |url= http://archive.rubicon-foundation.org/8084 |accessdate=2009-07-17}} 4. ^{{cite journal |vauthors=Vegfors M, Lennmarken C |title=Carboxyhaemoglobinaemia and pulse oximetry |journal=British Journal of Anaesthesia |volume=66 |issue=5 |pages=625–6 |date=May 1991 |pmid=2031826 |doi= 10.1093/bja/66.5.625|url=http://bja.oxfordjournals.org/cgi/pmidlookup?view=long&pmid=2031826}}
2 : Medical testing equipment|Oxygen |
随便看 |
|
开放百科全书收录14589846条英语、德语、日语等多语种百科知识,基本涵盖了大多数领域的百科知识,是一部内容自由、开放的电子版国际百科全书。