The Foucault knife-edge test was described in 1858 by French physicist Léon Foucault to measure conic shapes of optical mirrors, with error[1] margins measurable in fractions of wavelengths of light (or Angstroms, millionths of an inch, or nanometers).[2][3] It is commonly used by amateur telescope makers for figuring small astronomical mirrors. Its relatively simple, inexpensive apparatus can produce measurements more cost-effectively than most other testing techniques.[4][5]

It measures mirror surface dimensions by reflecting light into a knife edge at or near the mirror's centre of curvature. In doing so, it only needs a tester which in its most basic 19th century form consists of a light bulb, a piece of tinfoil with a pinhole in it, and a razor blade to create the knife edge. The testing device is adjustable along the X-axis (knife cut direction) across the Y-axis (optical axis), and must have measurable adjustment to 0.001 inch (25 µm) or better along lines parallel to the optical axis.[6] According to Texereau it amplifies mirror surface defects by a factor of one million, making them easily accessible to study and remediation.[7]

Foucault test basics

The mirror to be tested is placed vertically in a stand. The Foucault tester is set up at the distance of the mirror's radius of curvature (radius R is twice the focal length.) with the pinhole to one side of the centre of curvature (a short vertical slit parallel to the knife edge can be used instead of the pinhole). The tester is adjusted so that the returning beam from the pinhole light source is interrupted by the knife edge.

Viewing the mirror from behind the knife edge shows a pattern on the mirror surface. If the mirror surface is part of a perfect sphere, the mirror appears evenly lighted across the entire surface. If the mirror is spherical but with defects such as bumps or depressions, the defects appear greatly magnified in height. If the surface is paraboloidal, the mirror usually looks like a doughnut or lozenge although the exact appearance depends on the exact position of the knife edge.

It is possible to calculate how closely the mirror surface resembles a perfect parabola by placing a Couder mask,[8] Everest pin stick (after A. W. Everest)[9] or other zone marker[10] over the mirror. A series of measurements with the tester, finding the radii of curvature of the zones along the optical axis of the mirror (Y-axis). These data are then reduced and graphed against an ideal parabolic curve.

Other testing techniques

{{main|Ronchi test|Interferometry}}

A number of other tests are used which measure the mirror at the center of curvature. Some telescope makers use a variant of the Foucault test called a Ronchi test that replaces the knife edge with a grating (similar to a very coarse diffraction grating) comprising fine parallel wires, an etching on a glass plate, a photograph negative or computer printed transparency. Ronchi test patterns are matched to those of standard mirrors or generated by computer.

Other variants of the Foucault test include the Gaviola or Caustic test which can measure mirrors of fast f/ratio more accurately than the Foucault test which is limited to about (λ/8) wavelength accuracy on small and medium-sized mirrors. The Caustic test is capable of measuring larger mirrors and achieving a (λ/20) wave peak to valley accuracy by using a testing stage which is adjusted from side to side so as to measure each zone of each side of the mirror from the center of its curvature.[11]

The Dall null test uses a plano-convex lens placed a short distance in front of the pinhole. With the correct positioning of the lens, a parabolic mirror appears flat under testing instead of doughnut-shaped so testing is much easier and zonal measurements are not needed. 

There are a number of interferometric tests which have been used including the Michelson-Twyman and the Michelson method, both published in 1918, the Lenouvel method and the Fizeau method. Interferometric testing has been made more affordable in recent years by affordable lasers, digital cameras (such as webcams), and computers, but remains primarily an industrial methodology.

See also

  • Airy disk
  • Amateur telescope making
  • Angular resolution (see Angular resolution#Explanation for discussion of the Rayleigh criterion)
  • Diffraction-limited system
    • Huygens–Fresnel principle#Single slit diffraction
    • Knife-edge effect
  • Fabrication and testing of optical components
  • Null corrector
  • Strehl ratio

References

1. ^Texereau 1984 pp.68-70 section 2.25
2. ^Texereau 1984 p.70 section 2.26
3. ^{{Cite web| last = Sacek| first = Vladimir| authorlink = | title = 4.5.2. Foucault test| work = Notes on AMATEUR TELESCOPE OPTICS| publisher = Vladimir Sacek| date = 14 July 2006| url = http://www.telescope-optics.net/foucault_test.htm| doi = | accessdate = 18 December 2010}}
4. ^Texereau 1984 pp. 55-61 section 2.21
5. ^{{Cite web| last = Harbour| first = David A| authorlink = | title = Understanding Foucault: A Primer for Beginners (Second Edition)| work = | publisher = The ATM's Workshop| date = July 2001| url = http://www.atm-workshop.com/foucault.html| doi = | accessdate = 18 December 2010}}
6. ^Harbour 2008 p 39
7. ^Texereau 1984 pp. 57 section 2.21
8. ^Designing and calculating Couder screens for Foucault testing Ken Slater and Nils Olof Carlin
9. ^Stellafane ATM Build a Couder Mask; Build an Everest Pin Stick
10. ^Harbour 2008 pp 49-51
11. ^{{Cite web| last = Baldwin| first = Jeff| authorlink = | title = The Caustic Test| work = Valley Skies| publisher = Stockton Astronomical Society| date = September 2000| url = http://stocktonastro.org/Newsletter/TTN_CausticTest.html| doi = | accessdate = January 9, 2011}}
  • {{Cite book | last = Harbour | first = David A| title = Understanding Foucault: A primer for beginners (2nd edition)|editor = William J Welker| publisher = Sapphire Publications | date = July 2013 | isbn = 978-1-62374-003-0}}
  • {{Cite book| last = Texereau| first = Jean| title = How to Make a Telescope (second English edition)| publisher = Willman-Bell| date = 1984| location = Richmond, VA| pages = | url = | doi =| id = | isbn = 0-943396-04-2}}
  • {{Cite book| last = Thompson| first = Allyn J| title = Making Your Own Telescope| publisher = Sky Publishing| date = 15 April 1947| location = Cambridge, MA| pages = | url = | doi = | id =| asin = B0007DK32U| isbn = }}

Further reading

  • L. Foucault, "Description des procedees employes pour reconnaitre la configuration des surfaces optiques," Comptes rendus hebdomadaires des séances de l'Académie des Sciences, Paris, vol. 47, pages 958-959 (1858).
  • L. Foucault, "Mémoire sur la construction des télescopes en verre argenté," Annales de l'Observatoire impériale de Paris, vol. 5, pages 197-237 (1859).
{{DEFAULTSORT:Foucault Knife-Edge Test}}

5 : Amateur astronomy|Measuring instruments|Mirrors|Optical devices|Telescopes

随便看

 

开放百科全书收录14589846条英语、德语、日语等多语种百科知识,基本涵盖了大多数领域的百科知识,是一部内容自由、开放的电子版国际百科全书。

 

Copyright © 2023 OENC.NET All Rights Reserved
京ICP备2021023879号 更新时间:2024/11/10 18:57:30