Liquid junction potential occurs when two solutions of electrolytes of different concentrations are in contact with each other. The more concentrated solution will have a tendency to diffuse into the comparatively less concentrated one. The rate of diffusion of each ion will be roughly proportional to its speed in an electric field. If the anions diffuse more rapidly than the cations, they will diffuse ahead into the dilute solution, leaving the latter negatively charged and the concentrated solution positively charged. This will result in an electrical double layer of positive and negative charges at the junction of the two solutions. Thus at the point of junction, a potential difference will develop because of the ionic transfer. This potential is called liquid junction potential or diffusion potential which is non-equilibrium potential. The magnitude of the potential depends on the relative speeds of the ions' movement.

Calculation

The liquid junction potential cannot be measured directly but calculated. The Electromotive force (EMF) of a concentration cell with transference includes the liquid junction potential.

The EMF of a concentration cell without transport is:

where a1 and a2 are activities of HCl in the two solutions, R is the Universal Gas Constant, T is the temperature and F is Faraday's Constant.

The EMF of a concentration cell with transport (including the ion transport number) is:

where a2 and a1 are activities of HCl solutions of right and left hand electrodes respectively and tM be transport number of Cl

Liquid Junction potential is the difference between the two EMFs of the two concentration cells, with and without ionic transport:

Elj= Ewt – Ent = (tM – 1) RT/F . ln (a2/a1)

Elimination

The liquid junction potential interferes with the exact measurement of the electromotive force of a chemical cell, so its effect should be minimized as much as possible for accurate measurement. The most common method of eliminating the liquid junction potential is to place a salt bridge consisting of a saturated solution of potassium chloride (KCl) and ammonium nitrate (NH4NO3) with lithium acetate (CH3COOLi) between the two solutions constituting the junction. When such a bridge is used, the ions in the bridge are present in large excess at the junction and they carry almost the whole of the current across the boundary. The efficiency of KCl/NH4NO3 is connected with the fact that in these salts, the transport numbers{{Clarify|date=June 2013}} of anions and cations are the same.

See also

  • Concentration cell
  • Ion transport number
  • ITIES

References

  • Advanced Physical Chemistry by Gurtu & Snehi
  • Principles of Physical Chemistry by Puri, Sharma, Pathania

External links

  • Open source Liquid Junction Potential calculator
  • [https://www.youtube.com/watch?v=qQoDML0miVg Junction Potential Explanation Video]

4 : Diffusion|Ions|Physical chemistry|Electrochemistry

随便看

 

开放百科全书收录14589846条英语、德语、日语等多语种百科知识,基本涵盖了大多数领域的百科知识,是一部内容自由、开放的电子版国际百科全书。

 

Copyright © 2023 OENC.NET All Rights Reserved
京ICP备2021023879号 更新时间:2024/9/22 14:18:23