词条 | Masimo |
释义 |
| name = | logo = | type = Public | traded_as = {{NASDAQ|MASI}} S&P 400 Component | founder = Joe E. Kiani | location_city = Irvine, California 92618 | location_country = {{nowrap|United States of America}} 92618 | area_served = Worldwide | industry = Medical Technology Medical Devices Medical Equipment | num_employees = 3,500 (2014) | revenue = {{increase}}US $694.6 million (2016) [1] | homepage = {{URL|www.masimo.com}} }}Masimo is an American manufacturer of noninvasive patient monitoring technologies based in Irvine, California.[2] The company sells more pulse oximetry to hospitals than any other company.[3] Masimo was founded in 1989 by electrical engineer Joe Kiani, who was later joined by fellow engineer Mohamed Diab.[4] Masimo invented measure-through motion and low perfusion pulse oximetry, known as Masimo SET (Signal Extraction Technology). Masimo has been recognized for its intellectual property and for being one of the most innovative companies in the medical device industry.[5] The company went public in 2007[6] and is currently traded on the NASDAQ stock exchange under the symbol MASI. In 2011, Forbes named Masimo to its list of top 20 public companies under a billion dollars in revenue, based on earnings growth, sales growth, and return on equity.[7][8] In 2012, Joe Kiani, founder, CEO and Chairman of the Board was named the Ernst & Young National Entrepreneur of the Year - 2012 Life Sciences Award Winner. Kiani was recognized for "revolutionizing the health care industry by taking risks to create and commercialize noninvasive patient monitoring devices, which include an array of sensors that lead to improved accuracy, a reduction in the overall number of false readings, and ultimately, reduced cost of care."[9] TechnologySignal Extraction Technology (SET) pulse oximetryPulse oximetry uses two light emitting diodes (LEDs), one red and one infrared, to measure the absorption of light and translates that into the percentage of hemoglobin molecules that are bound with oxygen, which is called arterial oxygen saturation (SpO2). Conventional pulse oximetry assumes that arterial blood is the only blood moving (pulsating) in the measurement site. However, during patient motion, the venous blood also moves, which can cause conventional pulse oximetry to under-read SpO2 levels because it cannot distinguish between the arterial and venous blood.[10][11] SET identifies the venous blood signal (which has a lower oxygen saturation level than arterial blood), isolates it, and uses adaptive filters to cancel the noise and extract the arterial signal in order to report accurate SpO2 and pulse rate. In addition, SET pulse oximetry provides perfusion index (PI) and pleth variability index (PVI). Multiple studies have shown that compared to non-SET pulse oximeters, SET increases the ability to detect life-threatening events and reduces false alarms during challenging conditions.[12][13] Additional studies have also shown the impact of SET on patient outcomes, such as helping clinicians:
In 2011, the American Academy of Pediatrics and the U.S. Department of Health and Human Services recommended mandatory screening for all newborns, using "motion-tolerant pulse oximeters that report functional oxygen saturation have been validated in low perfusion conditions".[21] To make this recommendation, the CCHD workgroup relied on two independent studies that exclusively used SET pulse oximetry to assess newborns. In 2012, Masimo received FDA 510(k) clearance for devices and sensors with labeling for screening newborns for CCHD. It marked the first time the FDA cleared specific labeling indicating the use of pulse oximeters, in conjunction with a physical examination, to screen newborns for CCHD.[22] In 2012, the National Health Service (NHS) Technology Adoption Centre in the United Kingdom advised hospitals to use Intraoperative Fluid Management Technologies as a way to improve patient outcomes, and included Masimo's PVI among technologies available for helping clinicians manage fluid during surgeries.[23] In 2013, the French Society for Anaesthesia and Intensive Care (SFAR) added PVI to its guidelines for optimal hemodynamic management of surgical patients.[24] rainbow Pulse CO-Oximetryrainbow Pulse CO-Oximetry uses more than seven wavelengths of light to continuously and noninvasively measure hemoglobin (SpHb), carboxyhemoglobin (SpCO), and methemoglobin (SpMet), in addition to oxygen saturation (SpO2), pulse rate, perfusion index (Pi), and pleth variability index (PVi).[25] A study at Massachusetts General Hospital showed that SpHb monitoring helped clinicians decrease the frequency of patients receiving blood transfusions during surgery from 4.5% to 0.6%.[26] Another study from Cairo University showed that SpHb monitoring helped clinicians reduce blood transfusions in high blood loss surgery by an average of 0.9 units per patient.[27] Emergency department studies have shown that SpCO helps clinicians increase the detection of carbon monoxide (CO) poisoning and decreases the time to treatment compared to invasive methods.[28][29][30] The Pronto-7 device for noninvasive spot checking of hemoglobin, along with SpO2 and pulse rate, has been recognized with a gold Medical Design Excellence Award.[31] The World Health Organization called noninvasive hemoglobin an "innovative medical technology for cost-effectively addressing global health concerns and needs".[32] In October 2014, Masimo announced CE Mark of Oxygen Reserve Index or ORi, the company’s 11th noninvasive parameter, which provides real-time visibility to oxygenation status. ORi is intended to supplement, not replace, oxygen saturation (SpO2) monitoring and partial pressure of oxygen (PaO2) measurements. ORi can be trended and has optional alarms to notify clinicians of changes in a patient’s oxygen reserve, and may enable proactive interventions to avoid hypoxia and unintended hyperoxia. Noninvasive Patient MonitoringPatient SafetyNetPatient SafetyNet is a remote monitoring and notification system designed for patients on medical/surgical care floors.[33] A large study by Dartmouth-Hitchcock Medical Center showed Patient SafetyNet helped clinicians achieve a 65% reduction in distress codes and rescue activations and a 48% decrease in patient transfers to intensive care units (ICU), yielding a savings of 135 Intensive Care Unit (ICU) days annually for an annual opportunity-cost savings of $1.48 million.[34][35] ECRI Institute gave Dartmouth its Health Devices Achievement Award for its use of Patient SafetyNet to prevent "severe patient harm".[36] Masimo has introduced Halo Index in the Patient SafetyNet system, combining multiple physiologic parameters into one number to help clinicians assess overall patient status.[37] Rainbow acoustic monitoringRainbow acoustic monitoring provides noninvasive and continuous measurement of respiration rate using an adhesive sensor with an integrated acoustic transducer that is applied to the patient's neck.[38][39] Researchers have evaluated acoustic respiration rate (RRa) and found the acceptable accuracy and significantly fewer false alarms than traditional respiration rate monitoring methods, end-tidal carbon dioxide (EtCO2) and impedance pneumography.[40] SedLine brain function monitoringIn 2010, Masimo began offering brain function monitoring to measure the effects of anesthesia and sedation by monitoring both sides of the brain's electrical activity (EEG). Studies have shown this results in more individualized titration and improved care.[41] Capnography and gas monitoringIn 2012, Masimo began offering ultra-compact mainstream and sidestream capnography as well as multigas analyzers for end-tidal carbon dioxide (CO2), nitrous oxide (N2O), oxygen (O2), and anesthetic agents, for use in the operating room, procedural sedation, and in intensive care units (ICU).[42] A multi-center study at Cincinnati Children's Hospital Medical Center, University Medical Center (Tucson, Arizona), and Children's Medical Center (Dallas), found that respiratory rate measured from noninvasive, acoustic monitoring had similar accuracy and precision as nasal capnography, the current standard of care when used in pediatric patients.[43] Radius-7On December 1, 2014, Masimo announced FDA 510(k) clearance of Radius-7 for the Root patient monitoring and connectivity platform, the first and only wearable, wireless monitor with Masimo’s rainbow SET technology, enabling early identification of clinical deterioration while offering patients continuous monitoring with freedom of movement. Radius-7 attaches to the patient’s arm or can be placed alongside the patient in their bed, allowing untethered monitoring. Studies have shown that patient mobility is a key factor in more rapid patient recovery.[44] iSpO2 pulse oximeter for smart phones and tabletsiSpO2 pulse oximeter was awarded the Hot Product Award at the 2013 EMS Today Conference & Exposition.[45] Supported CausesClinton Global InitiativeIn 2012, Masimo embarked on its first Commitment to Action with the Clinton Global Initiative (CGI) to solve the global problem of maternal mortality and anemia. The $1 million, two-year project initially focuses on five villages in Liberia and Uganda – two countries where the epidemics of maternal mortality and anemia are among the worst.[46] Patient Safety Movement FoundationIn 2013, Masimo founder, Chairman and CEO Joe Kiani, created the nonprofit Patient Safety Movement Foundation with a mission to eliminate the more than 200,000[47] preventable patient deaths that occur in U.S. hospitals each year. The foundation holds annual Patient Safety, Science & Technology Summits, featuring leaders from healthcare, industry, and government; former President Bill Clinton has served as the keynote speaker. References1. ^{{cite web|url=http://masimocorp.gcs-web.com/static-files/b99fe298-4f62-4b3b-bb5a-de8532c99dea; Homepage |publisher=masimo.com |accessdate=2017-07-27}} 2. ^{{cite web|url=http://finance.google.com/finance?q=NASDAQ:MASI |title=Masimo Corporation: NASDAQ:MASI quotes & news - Google Finance |publisher=Finance.google.com |accessdate=2012-08-05}} 3. ^{{cite web|url=http://www.marketresearch.com/vendors/viewVendor.asp?VendorID=3689 |title=iData Research, Inc. Research Reports |publisher=Marketresearch.com |accessdate=2012-08-05}} 4. ^{{cite web|url=http://www.getnetworth.com/tag/masimo-age/ |title=Masimo age |publisher=getnetworth.com |accessdate=2014-10-09}} 5. ^{{cite web|url=http://www.medicalnewstoday.com/articles/46369.php |title=Masimo recognized as top 10 innovator in medical device industry |publisher=Medicalnewstoday.com |accessdate=2012-08-05}} 6. ^{{cite web|url=http://www.nasdaq.com/reference/200808/market_open_080708.stm |title=Joe Kiani, CEO, Chairman and Founder of Masimo Corporation, rings the NASDAQ opening bell |publisher=Nasdaq.com |date=2008-08-07}} 7. ^{{cite web |url=https://www.forbes.com/sites/kurtbadenhausen/2011/10/19/the-top-20-small-public-companies-in-america/|title=The top 20 small public companies in America |publisher=Forbes.com|first=K|last=Badenhausen|date=2011-10-19}} 8. ^{{cite web|url=https://www.forbes.com/pictures/mli45gdjh/19-masimo|title=#19 Masimo|publisher=Forbes.com|first=K|last=Badenhausen|date=2011-10-19}} 9. ^{{cite web|url=http://www.prnewswire.com/news-releases/creator-of-non-invasive-patient-monitoring-devices-masimo-corporation-founder-and-ceo-joe-kiani-named--ernst--young-national-entrepreneur-of-the-year-2012-life-sciences-award-winner-179843111.html|title=Creator of non-invasive patient monitoring devices: Masimo Corporation founder and CEO Joe Kiani named Ernst & Young National Entrepreneur Of The Year 2012 Life Sciences Award Winner|publisher=PRNewswire.com |date=2012-11-18}} 10. ^{{cite journal |pmc=2148612 |first1=G |last1=Mardirossian |first2=RE |last2=Schneider |year=1992|title=Limitations of pulse oximetry |journal=Anesth Prog |volume=39 |issue=6 |pages=194–6 |pmid=8250340}} 11. ^{{cite journal |pmid=3323062 |year=1987 |last1=Barker |first1=SJ |last2=Tremper |first2=KK |title=Pulse oximetry: Applications and limitations |volume=25 |issue=3 |pages=155–75 |journal=Int Anesthesiol Clin |doi=10.1097/00004311-198702530-00010}} 12. ^{{cite journal |pmid=10825316 |year=2000 |last1=Malviya |first1=S |last2=Reynolds |first2=PI |last3=Voepel-Lewis |first3=T |last4=Siewert |first4=M |last5=Watson |first5=D |last6=Tait |first6=AR |last7=Tremper |first7=K |title=False alarms and sensitivity of conventional pulse oximetry versus the SET technology in the pediatric postanesthesia care unit |journal=Anesth Analg |volume=90 |issue=6 |pages=1336–40 |doi=10.1097/00000539-200006000-00013}} 13. ^1 {{cite web |last1=Barker |first1=SJ |year=2002|url=https://www.ncbi.nlm.nih.gov/pubmed?term=barker%202002%20pulse%20oximetry%20masimo |title="Motion-resistant" pulse oximetry: a comparison of old and new models |journal=Anesth Analg |volume=95 |issue=4 |pages=967–72 |pmid=12351278 |doi=10.1213/00000539-200210000-00033}} 14. ^{{cite journal |doi=10.1111/j.1651-2227.2010.02001.x |title=Prevention of retinopathy of prematurity in preterm infants through changes in clinical practice and SpO2 technology |year=2011 |last1=Castillo |first1=A |last2=Deulofeut |first2=R |last3=Critz |first3=A |last4=Sola |first4=A |journal=Acta Paediatrica |volume=100 |issue=2 |pages=188–92 |pmid=20825604 |pmc=3040295}} 15. ^{{cite journal |doi= 10.1038/jp.2013.122|title=Temporal quantification of oxygen saturation ranges: an effort to reduce hyperoxia in the neonatal intensive care unit |year=2013 |last1=Bizzarro |first1=M |last2=Ly |first2=F |last3=Katz |first3=K |last4=Shabanova |first4=V |last5=Ehrenkranz |first5=R |last6=Bhandari |first6=V |journal=J Perinatol |volume=34 |pages=33–8}} 16. ^{{cite journal |doi=10.1136/bmj.a3037 |last1=De-Wahl |first1=GA |last2=Wennergren |first2=M |last3=Sandberg |first3=K |last4=Mellander |first4=M |last5=Bejlum |first5=C |last6=Inganas |first6=L |last7=Eriksson |first7=M |last8=Segerdahl |first8=N |last9=Agren |first9=A |last10=Ekman-Joelsson |first10=BM |last11=Sunnegardh |first11=J |last12=Verdicchio |first12=M |last13=Ostman-Smith |first13=I |year=2009 |title=Impact of pulse oximetry screening on the detection of duct dependent congenital heart disease: A Swedish prospective screening study in 39,821 newborns |journal=Br Med J |volume=338 |page=a3037}} 17. ^{{cite journal |doi=10.1097/00003246-200208000-00010|last1=Durbin |first1=CG |last2=Rostow |first2=SK |year=2002 |title=More reliable oximetry reduces the frequency of arterial blood gas analysis and hastens oxygen weaning following cardiac surgery; a prospective randomize trial of the clinical impact of a new technology |journal=Crit Care Med |volume=30 |issue=8 |pages=1735–40}} 18. ^{{cite journal |doi=10.1097/ALN.0b013e3181ca7a9b |last1=Taenzer |first1=AH |last2=Pyke |first2=JB |last3= McGrath |first3=SP |last4=Blike |first4=GT |year=2010 |title=Impact of pulse oximetry surveillance on rescue events and intensive care unit (ICU) transfers: A before-and-after concurrence study |journal=Anesthesiology |volume=112 |pages=282–87 |pmid=20098128}} 19. ^{{cite news |last1=Taenzer |first1=AH |last2=Blike |first2=GT |year=2012 |title=Postoperative monitoring – the Dartmouth experience |publisher=APSF Spring-Summer Newsletter}} 20. ^{{cite journal |doi=10.1213/ANE.0b013e3181eb624f |last1=Forget |first1=P |last2=Lois |first2=F |last3=De Kock |first3=M |year=2010 |title=Goal-directed fluid management based on the pulse oximeter–derived pleth variability index reduces lactate levels and improves fluid management |journal=Anesth Analg |volume= |page=1}} 21. ^{{cite journal |doi=10.3310/hta16020|last1=Ewer |first1=AK |last2=Furmston|first2=AT |last3=Middleton|first3= LJ |last4=Deeks |first4=J |last5=Daniels |first5=JP |last6=Pattison |first6=HM |last7=Powell |first7=R |last8=Roberts |first8=TE |last9=Parton |first9=P |last10=Auguste |first10=P |last11=Bhoyar |first11=A |last12=Thangaratinam |first12=S |last13=Tonks |first13=AM |last14=Satodia |first14=P |last15=Deshpande |first15=S |last16=Kumararatne |first16=B |last17=Sivakumar |first17=S |last18=Mupanemunda |first18=R |last19=Khan |first19=KS |year=2012 |title=Pulse oximetry as a screening test for congenital heart defects in newborn infants: a test accuracy study with evaluation of acceptability and cost-effectiveness |journal=Health Technol Assess |volume=16 |pages=1–184}} 22. ^{{cite press release |title=Masimo oximeters and neonatal sensors receive FDA 510(k) clearance with labeling for use in newborn screening for Critical Congenital Heart Disease (CCHD) |url=http://www.prnewswire.com/news-releases/masimo-oximeters-and-neonatal-sensors-receive-fda-510k-clearance-with-labeling-for-use-in-newborn-screening-for-critical-congenital-heart-disease-cchd-170962421.html |publisher=PRNewswire.com |date=2012-09-26}} 23. ^{{cite web|url=http://www.ntac.nhs.uk/NewsAndEvents/IOFM_Technology_Adoption_Pack_Published.aspx |title=IOFM technology adoption pack published |publisher=Ntac.nhs.uk |accessdate=2012-08-05}} 24. ^{{cite news |last1=Vallet|first1=B |last2=Blanloeil |first2=Y |last3=Cholley |first3=B |last4=Orliaguet |first4=G |last5=Pierre |first5=S |last6=Tavernier |first6=B |year=2012 |title=Strategy for perioperative vascular filling - guidelines for perioperative haemodynamic optimization |format=Experts’ formalized recommendations, French Society of Anaesthesia and Intensive Care (SFAR), validation by the administrative council of SFAR on 19 October 2012}} 25. ^{{cite web|url=http://www.medicalnewstoday.com/articles/59424.php |title=Masimo Rainbow SET Pulse CO-Oximetry technology shown effective and efficient in detecting carbon monoxide poisoning in multiple clinical settings |publisher=Medicalnewstoday.com |accessdate=2012-08-05}} 26. ^{{cite web|url=http://www.anesthesiologynews.com/ViewArticle.aspx?d=PRN&d_id=21&i=November+2010&i_id=679&a_id=16133 |title=Anesthesiology News |publisher=Anesthesiology News |accessdate=2012-08-05}} 27. ^{{cite news |last1=Awada |first1=WNFM |last2=Maher |first2=F |date=2013 |title=Reduction in red blood cell transfusions during neurosurgery with noninvasive and continuous hemoglobin monitoring|page=51}} 28. ^{{cite journal |pmid=18226877 |doi=10.1016/j.jemermed.2007.12.004 |last1=Suner |first1=S |last2=Partridge |first2=R |last3=Sucov |first3=A |last4=Valente |first4=J |last5=Chee |first5=K |last6=Hughes |first6=A |last7=Jay |first7=G |year=2008 |title=Non-invasive pulse co-oximetry screening in the emergency department identifies occult carbon monoxide toxicity |journal=J Emerg Med |volume=34 |issue=4 |pages=441–50}} 29. ^{{cite journal |last1=Roth|first1=D |last2=Schreiber |first2=W |last3=Herkner |first3=H |last4=Havel |first4=C |year=2014 |title=Prevalence of carbon monoxide poisoning in patients presenting to a large emergency department |journal=Int J Clin Pract |volume=68 |issue=10 |pages=1239–45 |doi=10.1111/ijcp.12432 |pmid=24698635}} 30. ^{{cite journal |doi=10.1016/j.ajem.2012.03.026 |last1=Hampson |first1=N |year=2012 |title=Noninvasive pulse co-oximetry expedites evaluation and management of patients with carbon monoxide poisoning |journal=Am J Emerg Med |volume=30 |issue=9 |pages=2021–4}} 31. ^{{cite web|url=http://www.canontradeshows.com/expo/awards/awards/index.php?catId=-1&year=2011&view=View |title=Award winners | medical design excellence awards |publisher=Canontradeshows.com |date=2005-10-22 |accessdate=2012-08-05}} 32. ^{{cite news| url=http://www.healthcarereview.com/2010/08/noninvasive-hemoglobin-test-first-ouchless-bloodless-makes-world-health-organizations-who-list-of-innovative-medical-technologies-that-address-global-health-concerns-and-needs/ |date=2010-08-31 |title=Noninvasive hemoglobin test (first ouchless & bloodless) makes world health organization’s (WHO) list of innovative medical technologies that address global health concerns and needs… |publisher= www.healthcarereview.com}} 33. ^{{cite web |url=http://medgadget.com/archives/2007/10/masimo_patient_safetynet.html |last1=Ostrovsky |first1=G |date=2007-10-17 |title=Masimo Patient SafetyNet |publisher=Medgadget.com}} 34. ^{{cite web|url=http://dms.dartmouth.edu/news/2010/03/05_taenzer.shtml |date=2010-03-05 |title=Geisel School of Medicine - Closer watch, fewer Intensive Care Unit (ICU) trips, Dartmouth anesthesiologists find |publisher=Dms.dartmouth.edu}} 35. ^{{cite web|url=http://www.apsf.org/newsletters/html/2012/spring/index.htm |title=APSF Newsletter Spring-Summer 2012 |publisher=Apsf.org |accessdate=2012-08-05}} 36. ^{{cite web|url=https://www.ecri.org/Press/Pages/Health_Devices_Award_Winner_2009.aspx |title=ECRI Institute announces winner of 4th annual health devices achievement award |publisher=Ecri.org |accessdate=2012-08-05}} 37. ^{{cite web|url=http://www.medgadget.com/archives/2010/10/masimo_to_release_new_halo_index_radical_7_pulse_oximeter_patient_safetynet_monitoring_system.html |last1=Ostrovsky |first1=G |date=2010-10-14 |title=Masimo to Release New Halo Index, Radical 7 Pulse Oximeter, Patient SafetyNet Monitoring System |publisher=Medgadget.com}} 38. ^{{cite web |url=http://www.rtmagazine.com/news/2009-12-01_01.asp |title=FDA clears Masimo Rainbow SET Acoustic Respiration Rate Monitor | News | RT: for decision makers in respiratory care |publisher=Rtmagazine.com |accessdate=2012-08-05 |deadurl=yes |archiveurl=https://web.archive.org/web/20120321162436/http://www.rtmagazine.com/news/2009-12-01_01.asp |archivedate=2012-03-21 |df= }} 39. ^{{cite web|url=http://www.asaabstracts.com/strands/asaabstracts/abstract.htm;jsessionid=ED84A8C2F2FA0F72B892E720DA7F87A2?year=2010&index=15&absnum=1947 |last1=Kumpula |first1= JC |last2=Rhonda |first2=D |last3=Harrison |first3=RD |date=2010-10-18 |title=Accuracy of acoustic respiration rate monitoring in an acute nursing unit |publisher=ASA Abstracts |format=Abstract |id=A1079}} 40. ^{{cite news |last1=Goudra |first1=B |last2=Penugonda |first2=L |date=2011 |title=Monitoring respiration in upper GI endoscopy anesthesia |format=ASA Presentation |id=A246}} 41. ^{{cite journal|url=http://journals.lww.com/anesthesiology/Fulltext/2002/07000/Patient_State_Index__Titration_of_Delivery_and.12.aspx |last1=Drover |first1=DR |last2=Lemmens |first2=HJ |last3=Pierce |first3=ET |last4=Plourde |first4=G |last5=Loyd |first5=G |last6=Ornstein |first6=E |last7=Prichep |first7=LS |last8=Chabot |first8=RJ |last9=Gugino |first9=L |date=2002 |title=Patient state index: Titration of delivery and recovery from propofol, alfentanil, and nitrous oxide anesthesia |journal=Anesthesiology |volume=97 |issue=1 |pages=82–9 |pmid=12131107 |doi=10.1097/00000542-200207000-00012}} 42. ^{{cite web|url=http://medcitynews.com/2012/08/masimo-enters-noninvasive-multigas-monitoring-including-capnography-with-acquisition-of-phasein/ |date=2012-08-01 |title=Masimo enters noninvasive multigas monitoring, including capnography, with acquisition of PHASEIN |publisher=Medcitynews.com |accessdate=2012-08-05}} 43. ^{{cite journal |last1=Patino|first1=M |last2=Redford|first2=DT|last3=Quigley |first3=TW |last4=Mahmoud |first4=M |last5=Kurth |first5=CD |last6=Szmuk |first6=P |date=Dec 2013 |title=Accuracy of acoustic respiration rate monitoring in pediatric patients |journal=Paediatr Anaesth |month= |volume=23 |issue=12 |pages=1166–73 |doi=10.1111/pan.12254 |pmid=24033591}} 44. ^Needham D, Korupolu R, Zanni J, Pradhan P, Colantuoni E, Palmer J, Brower R, Fan E. "Early Physical Medicine and Rehabilitation for Patients With Acute Respiratory Failure: A Quality Improvement Project." Archives of Physical Medicine and Rehabilitation Vol 91, Issue 4, PP 536–542, April 2010 45. ^{{cite web|url=http://www.rtmagazine.com/2013/05/masimo-patient-monitoring-devices-earn-awards-from-jems/|title=Masimo Patient Monitoring Devices Earn Awards From JEMS|accessdate=2014-07-10}} 46. ^{{cite web|url=http://www.starafrica.com/en/news/detail-news/view/masimo-announces-1-million-commitment-t-254163.html |date=2012-09-25 |title=Masimo announces $1 million commitment to action with the Clinton Global Initiative to solve maternal mortality & anemia |publisher=StarAfrica.com}} 47. ^{{cite |year=2013 |title=A new, evidence-based estimate of patient harms associated with hospital care |journal=Journal of Patient Safety |volume=9 |issue=3 |pages=122–8 |pmid=23860193 |first1=James |last1=JT}} Resources
7 : Companies listed on NASDAQ|Medical equipment|Companies based in Irvine, California|Medical technology companies of the United States|Health care companies based in California|Manufacturing companies based in the Greater Los Angeles Area|Manufacturing companies established in 1989 |
随便看 |
|
开放百科全书收录14589846条英语、德语、日语等多语种百科知识,基本涵盖了大多数领域的百科知识,是一部内容自由、开放的电子版国际百科全书。