词条 | Power over Ethernet | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
释义 |
Power over Ethernet or PoE describes any of several standard or ad-hoc systems which pass electric power along with data on twisted pair Ethernet cabling. This allows a single cable to provide both data connection and electric power to devices such as wireless access points, IP cameras, and VoIP phones. There are several common techniques for transmitting power over Ethernet cabling. Three of them have been standardized by IEEE 802.3 since 2003. These standards are known as Alternative A, Alternative B, and 4PPoE. For 10BASE-T and 100BASE-TX, only two of the four signal pairs in typical Cat 5 cable are used. Alternative B separates the data and the power conductors, making troubleshooting easier. It also makes full use of all four twisted pairs in a typical Cat 5 cable. The positive voltage runs along pins 4 and 5, and the negative along pins 7 and 8. Alternative A transports power on the same wires as data for 10 and 100 Mbit/s Ethernet variants. This is similar to the phantom power technique commonly used for powering condenser microphones. Power is transmitted on the data conductors by applying a common voltage to each pair. Because twisted-pair Ethernet uses differential signaling, this does not interfere with data transmission. The common-mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. For Gigabit Ethernet and faster, all four pairs are used for data transmission, so both Alternatives A and B transport power on wire pairs also used for data. 4PPoE provides power using all four pairs of a twisted-pair cable. This enables higher power for applications like PTZ cameras, high-performance wireless access points, or even charging laptop batteries. In addition to standardizing existing practice for spare-pair (Alternative B), common-mode data pair power (Alternative A) and 4-pair transmission (4PPoE), the IEEE PoE standards provide for signaling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Standards developmentThe original IEEE 802.3af-2003[1] PoE standard provides up to {{nowrap|15.4 W}} of DC power (minimum {{Nowrap|44 V DC}} and {{Nowrap|350 mA}}[2][3]) on each port.[4] Only {{Nowrap|12.95 W}} is assured to be available at the powered device as some power dissipates in the cable.[5] The updated IEEE 802.3at-2009[6] PoE standard also known as PoE+ or PoE plus, provides up to {{Nowrap|25.5 W}} of power for "Type 2" devices.[7] The 2009 standard prohibits a powered device from using all four pairs for power.[8] Both of these standards have since been incorporated into the IEEE 802.3-2012 publication.[9] The IEEE 802.3bu-2016[10] amendment introduced single-pair Power over Data Lines (PoDL) for the single-pair Ethernet standards 100BASE-T1 and 1000BASE-T1 intended for automotive and industrial applications. On the two-pair or four-pair standards power is transmitted only between pairs, so that within each pair there is no voltage present other than that representing the transmitted data. With single-pair Ethernet, power is transmitted in parallel to the data. PoDL defines 10 power classes, ranging from .5 to 50 W (at PD). Looking at ways of increasing the amount of power transmitted, IEEE has defined IEEE 802.3bt 4PPoE in September 2018.[11] The standard introduces two additional power types: up to 55 W (Type 3) and up to 90-100 W (Type 4). Each pair of twisted pairs needs to handle a current of up to 600 mA (Type 3) or 960 mA (Type 4).[12] Additionally, support for 2.5GBASE-T, 5GBASE-T and 10GBASE-T is included.[13] This development opens the door to new applications and expands the use of applications such as high-performance wireless access points and surveillance cameras. Uses{{Gallery|title=Products using PoE|width=250|File:IP camera Ethernet power.jpg|alt1=|An IP camera powered by Power over Ethernet |File:1140E.jpg|alt2=|Avaya IP Phone 1140E with PoE support |File:CableFree-FOR3-Microwave-Link-20180410.jpg|alt3=|A CableFree FOR3 microwave link installed in the UAE: a full outdoor radio featuring proprietary high power over Ethernet }} Examples of devices powered by PoE include:[14]
TerminologyPower sourcing equipment"Power sourcing equipment" (PSE) are devices that provide (source) power on the Ethernet cable. This device may be a network switch, commonly called an endspan (IEEE 802.3af refers to it as endpoint), or an intermediary device between a non-PoE-capable switch and a PoE device, an external PoE injector, called a midspan device.[17] Powered deviceA "Powered device" (PD) is any device powered by PoE, thus consuming energy. Examples include wireless access points, VoIP phones, and IP cameras. Many powered devices have an auxiliary power connector for an optional external power supply. Depending on the design, some, none, or all of the device's power can be supplied from the auxiliary port,[18][19] with the auxiliary port also sometimes acting as backup power in case PoE-supplied power fails. Power management features and integrationAdvocates of PoE expect PoE to become a global long term DC power cabling standard and replace a multiplicity of individual AC adapters, which cannot be easily centrally managed.[20] Critics of this approach argue that PoE is inherently less efficient than AC power due to the lower voltage, and this is made worse by the thin conductors of Ethernet. Advocates of PoE, like the Ethernet Alliance, point out that quoted losses are for worst case scenarios in terms of cable quality, length and power consumption by powered devices.[21] In any case, where the central PoE supply replaces several dedicated AC circuits, transformers and inverters, the power loss in cabling can be justifiable. Integrating EEE and PoEAfter integration of PoE with the IEEE 802.3az Energy-Efficient Ethernet (EEE) standard potentially produces additional energy savings. Pre-standard integrations of EEE and PoE (such as Marvell's EEPoE outlined in a May 2011 white paper) claim to achieve a savings upwards of 3 W per link. This saving is especially significant as higher power devices come online. Marvell claims that: "With the evolution of PoE from a fairly low power source (up to 12.95 W per port) to one with devices of up to 25.5 W, the direct current (DC) power losses over Ethernet cables increased exponentially. Approximately 4.5 W/port of power is wasted on a CAT5, CAT5e, CAT6 or CAT6A cable...after 100 m... EEE typically saves no more than 1 W per link, so addressing the 4.5 W per link loss from PoE transmission inefficiency would provide much more incremental savings. New energy-efficient PoE (EEPoE) technology can increase efficiency to 94% while transmitting over the same 25 ohm cable, powering IEEE 802.3at-compliant devices in synchronous 4-pairs. When utilizing synchronous 4-pairs, powered devices are fed using all the available wires. For example, on a 24-port IEEE 802.3at-2009 Type 2 system (delivering 25.5 W per port), more than 50 W are saved."[22] Standard implementationStandards-based Power over Ethernet is implemented following the specifications in IEEE 802.3af-2003 (which was later incorporated as clause 33 into IEEE 802.3-2005) or the 2009 update, IEEE 802.3at. The standards require category 5 cable or better for high power levels but allow using category 3 cable if less power is required.[23] Power is supplied as a common-mode signal over two or more of the differential pairs of wires found in the Ethernet cables and comes from a power supply within a PoE-enabled networking device such as an Ethernet switch or can be injected into a cable run with a midspan power supply. A midspan power supply, also known as a PoE power injector, is an additional PoE power source that can be used in combination with a non-PoE switch. A phantom power technique is used to allow the powered pairs to also carry data. This permits its use not only with 10BASE-T and 100BASE-TX, which use only two of the four pairs in the cable, but also with 1000BASE-T (gigabit Ethernet), which uses all four pairs for data transmission. This is possible because all versions of Ethernet over twisted pair cable specify differential data transmission over each pair with transformer coupling; the DC supply and load connections can be made to the transformer center-taps at each end. Each pair thus operates in common mode as one side of the DC supply, so two pairs are required to complete the circuit. The polarity of the DC supply may be inverted by crossover cables; the powered device must operate with either pair: spare pairs 4–5 and 7–8 or data pairs 1–2 and 3–6. Polarity is defined by the standards on data pairs, and ambiguously implemented for spare pairs, with the use of a diode bridge.
Notes: 1. ^{{citation |title=802.3af-2003 |date=June 2003}} 2. ^IEEE 802.3-2005, section 2, table 33-5, item 1 3. ^IEEE 802.3-2005, section 2, table 33-5, item 4 4. ^IEEE 802.3-2005, section 2, table 33-5, item 14 5. ^IEEE 802.3-2005, section 2, clause 33.3.5.2 6. ^{{citation |title=802.3at Amendment 3: Data Terminal Equipment (DTE) Power via the Media Dependent Interface (MDI) Enhancements |date=September 11, 2009}} 7. ^{{cite web |url=http://standards.ieee.org/announcements/stdbd_approves_ieee802.3at.html |title=Amendment to IEEE 802.3 Standard Enhances Power Management and Increases Available Power |publisher=IEEE |accessdate=2010-06-24}} 8. ^Clause 33.3.1 stating, "PDs that simultaneously require power from both Mode A and Mode B are specifically not allowed by this standard." 9. ^{{citation |title=IEEE 802.3-2012 Standard for Ethernet |date=December 28, 2012 |publisher=IEEE Standards Association}} 10. ^{{cite web|url=http://www.ieee802.org/3/bu/index.html |title=IEEE P802.3bu 1-Pair Power over Data Lines (PoDL) Task Force |date=2017-03-17 |accessdate=2017-10-30}} 11. ^{{Cite web|url=http://www.ieee802.org/3/bt/index.html |title=IEEE P802.3bt DTE Power via MDI over 4-Pair Task Force |date=2016-03-29 |accessdate=2018-10-11}} 12. ^IEEE 802.3bt 145.1.3 System parameters 13. ^{{cite web|url=http://www.ieee802.org/3/bt/public/jan16/hstewart_02_0116_baseline.pdf |title=IEEE P802.3bt/D1.5 Draft Standard for Ethernet – Amendment: Physical Layer and Management Parameters for DTE Power via MDI over 4-Pair |date=30 November 2015 |accessdate=2017-04-09}} 14. ^{{cite web |title=Power over Ethernet |work=Commercial web page |publisher=GarrettCom |url=http://www.garrettcom.co.uk/power-over-ethernet |accessdate=August 6, 2011 |deadurl=yes |archiveurl=https://web.archive.org/web/20110829043155/http://www.garrettcom.co.uk/power-over-ethernet |archivedate=August 29, 2011 |df= }} 15. ^{{cite web |title=The Bright New Outlook For LEDs: New Drivers, New Possibilities |work= Commercial Application Note |publisher= Maxim Integrated |url=http://www.maximintegrated.com/content/dam/files/products/campaigns/solutions/led-white-paper.pdf |accessdate= 27 April 2015}} 16. ^{{cite web |url=http://www.veracityglobal.com/products/ethernet-and-poe-devices/outreach-max.aspx |title=Ethernet Extender for POE and POE Plus equipment |accessdate=2015-10-26}} 17. ^Cisco Aironet technotes on 1000BASE-T mid-span devices, visited 18 July 2011 18. ^IEEE 802.3-2008, section 2, clause 33.3.5 19. ^IEEE 802.3at-2009, clause 33.3.7 20. ^{{citation |title=Banish Those "Wall Warts" With Power Over Ethernet |author=Dave Dwelley |work=Electronic Design |url=http://www.electronicdesign.com/displays/banish-those-wall-warts-power-over-ethernet |date=Oct 26, 2003 |access-date=2018-07-21}} 21. ^{{citation |url=https://www.cablinginstall.com/articles/2017/110/power-over-ethernet-cable-losses-ethernet-alliance.html |author1=David Tremblay |author2=Lennart Yseboodt |title=Clarifying misperceptions about Power over Ethernet and cable losses |date=November 10, 2017 |access-date=2018-07-21 |work=Cabling Installation and Maintenance}} 22. ^{{citation |url=http://www.marvell.com/switching/assets/Marvell-PoE-An-Energy-Efficient-Alternative.pdf |title=Power over Ethernet (PoE): An Energy-Efficient Alternative |date=May 2011 |author1=Roman Kleinerman |author2=Daniel Feldman |publisher=Marvell |access-date=2016-08-31}} 23. ^1 2 IEEE 802.3at-2009, clause 33.1.1c 24. ^{{cite web|url=http://www.ieee802.org/3/bt/public/may14/abramson_01_0514.pdf |title=Base Line Text for IEEE 802.3 BT |author1=Koussalya Balasubramanian |author2=David Abramson |date=May 2014 |accessdate=2017-04-02}} 25. ^Most switched power supplies within the powered device will lose another 10 to 25% of the available power to heat. 26. ^1 IEEE 802.3at-2009 Table 33-11 27. ^1 IEEE 802.3at-2009 Table 33-18 28. ^1 2 3 4 IEEE 802.3bt Table 145-1 29. ^1 IEEE 802.3at-2009 Table 33-1 30. ^1 IEEE 802.3at-2009 33.1.4 Type 1 and Type 2 system parameters 31. ^IEEE 802.3bt 145.3.1 PD Type definitions 32. ^IEEE 802.3bt 145.1.3.1 Cabling requirements 33. ^More stringent cable specification allows assumption of more current carrying capacity and lower resistance (20.0 Ω for Category 3 versus 12.5 Ω for Category 5). 34. ^{{citation |first1=Jacob |last1=Herbold |first2=Dave |last2=Dwelley |date=27 October 2003 |journal=Electronic Design |volume=51 |issue=24 |page=61 |url=http://elecdesign.com/Articles/Index.cfm?ArticleID=5945&pg=3 |archiveurl=https://web.archive.org/web/20050320054651/http://elecdesign.com/Articles/Index.cfm?ArticleID=5945&pg=3 |archivedate=2005-03-20 |title=Banish Those "Wall Warts" With Power Over Ethernet}} 35. ^1 IEEE 802.3-2008, section 2, table 33-12 36. ^1 IEEE 802.3at-2009, table 33-18 37. ^{{cite web |title=LTC4278 IEEE 802.3at PD with Synchronous No-Opto Flyback Controller and 12V Aux Support |url=http://cds.linear.com/docs/Datasheet/4278fa.pdf}} 2010-01-11 cds.linear.com 38. ^IEEE 802.3-2005, section 2, table 33-3 39. ^IEEE 802.3-2008, section 2, clause 33.3.4 40. ^IEEE 802.3 Clause 79.3.2 Power Via MDI TLV 41. ^1 2 IETF {{IETF RFC|3621}} 42. ^IEEE 802.1AB-2009 Annex F.3 Power Via MDI TLV 43. ^IETF {{IETF RFC|3621}} 44. ^1 {{cite web|title=LLDP / LLDP-MED Proposal for PoE Plus (2006-09-15)|url=http://www.ieee802.org/1/files/public/docs2006/ab-congdon-lldp-med-8023at-0906.pdf}}2010-01-10 45. ^{{cite web|title=Planning for Cisco IP Telephony > Network Infrastructure Analysis|url=http://www.ciscopress.com/articles/article.asp?p=385336&seqNum=2&rll=1}} 2010-01-12 ciscopress.com 46. ^{{cite web|title=Power over Ethernet on the Cisco Catalyst 6500 Series Switch|url=http://www.conticomp.com/PDF/CAT6500POE_ds.pdf|deadurl=yes|archiveurl=https://www.webcitation.org/5u2FxkQis?url=http://www.conticomp.com/PDF/CAT6500POE_ds.pdf|archivedate=2010-11-06|df=}} 2010-01-12 conticomp.com 47. ^{{cite web|title=Understanding the Cisco IP Phone 10/100 Ethernet In-Line Power Detection Algorithm - Cisco Systems|url=http://www.cisco.com/en/US/products/hw/phones/ps379/products_tech_note09186a00801189b5.shtml}} 2010-01-12 cisco.com 48. ^{{cite web |title=Cisco Universal Power Over Ethernet - Unleash the Power of your Network White Paper |url=http://www.cisco.com/c/en/us/products/collateral/switches/catalyst-4500-series-switches/white_paper_c11-670993.html |archive-url=https://web.archive.org/web/20171128140727/http://www.cisco.com/c/en/us/products/collateral/switches/catalyst-4500-series-switches/white_paper_c11-670993.html |archive-date=2017-11-28 |date=2014-07-11 |publisher=Cisco Systems}} 49. ^{{cite web |url=http://www.linear.com/products/power-over-ethernet_(poe)_interface_controllers | title=Power over Ethernet Interface Controllers}} 50. ^{{citation |url=http://www.poweroverethernet.com/sponsors.php?sponsor_id=12 |title=PowerDsine Limited |archive-url=https://web.archive.org/web/20120728191203/http://www.poweroverethernet.com/sponsors.php?sponsor_id=12 |archive-date=2012-07-28}} 51. ^{{cite web|title=Passive Power over Ethernet equipment, AC-DC and DC-DC|url=http://wifiqos.com/foscam.php}} 2013-06-28 wifiqos.com 52. ^{{cite web|title=Passive Power over Ethernet equipment, AC-DC and DC-DC|url=http://tyconpower.com/products/POE.htm}} 2010-02-18 tyconpower.com Powering devicesThree modes, A, B, and 4-pair are available. Mode A delivers power on the data pairs of 100BASE-TX or 10BASE-T. Mode B delivers power on the spare pairs. 4-pair delivers power on all four pairs. PoE can also be used on 1000BASE-T Ethernet, in which case there are no spare pairs and all power is delivered using the phantom technique. Mode A has two alternate configurations (MDI and MDI-X), using the same pairs but with different polarities. In mode A, pins 1 and 2 (pair #2 in T568B wiring) form one side of the 48 V DC, and pins 3 and 6 (pair #3 in T568B) form the other side. These are the same two pairs used for data transmission in 10BASE-T and 100BASE-TX, allowing the provision of both power and data over only two pairs in such networks. The free polarity allows PoE to accommodate for crossover cables, patch cables and Auto MDI-X. In mode B, pins 4–5 (pair #1 in both T568A and T568B) form one side of the DC supply and pins 7–8 (pair #4 in both T568A and T568B) provide the return; these are the "spare" pairs in 10BASE-T and 100BASE-TX. Mode B, therefore, requires a 4-pair cable. The PSE, not the PD, decides whether power mode A or B shall be used. PDs that implement only mode A or mode B are disallowed by the standard. The PSE can implement mode A or B or both. A PD indicates that it is standards-compliant by placing a 25 kΩ resistor between the powered pairs. If the PSE detects a resistance that is too high or too low (including a short circuit), no power is applied. This protects devices that do not support PoE. An optional power class feature allows the PD to indicate its power requirements by changing the sense resistance at higher voltages. To retain power, the PD must use at least 5–10 mA for at least 60 ms at a time. If the PD goes more than 400 ms without meeting this requirement, the PSE will consider the device disconnected and, for safety reasons, remove power.[34] There are two types of PSEs: endspans and midspans. Endspans (commonly called PoE switches) are Ethernet switches that include the power over Ethernet transmission circuitry. Midspans are power injectors that stand between a regular Ethernet switch and the powered device, injecting power without affecting the data. Endspans are normally used on new installations or when the switch has to be replaced for other reasons (such as moving from 10/100 Mbit/s to 1 Gbit/s), which makes it convenient to add the PoE capability. Midspans are used when there is no desire to replace and configure a new Ethernet switch, and only PoE needs to be added to the network.
IEEE 802.3at capable devices are also referred to as "type 2". An 802.3at PSE may also use layer2 communication to signal 802.3at capability.[37]
Class 4 can only be used by IEEE 802.3at (type 2) devices, requiring valid Class 2 and Mark 2 currents for the power up stages. An 802.3af device presenting a class 4 current is considered non-compliant and, instead, will be treated as a Class 0 device.[39] Configuration via Ethernet layer 2 LLDP
The setup phases are as follows:
The rules for this power negotiation are:
Non-standard implementationsCiscoSome Cisco manufactured WLAN access points and IP phones supporting a proprietary form of PoE many years before there was an IEEE standard for delivering PoE. Cisco's original PoE implementation is not software upgradeable to the IEEE 802.3af standard. Cisco's original PoE equipment is capable of delivering up to {{nowrap|10 W}} per port. The amount of power to be delivered is negotiated between the endpoint and the Cisco switch based on a power value that was added to the Cisco proprietary Cisco Discovery Protocol (CDP). CDP is also responsible for dynamically communicating the Voice VLAN value from the Cisco switch to the Cisco IP Phone. Under Cisco's pre-standard scheme, the PSE (switch) will send a Fast Link Pulse (FLP) on the transmit pair. The PD (device) connects the transmit line to the receive line via a low pass filter. And thus the PSE gets the FLP in return. And a common mode current between pair 1 and 2 will be provided resulting in {{nowrap|48 V DC}}[45] and {{nowrap|6.3 W}}[46] default of allocated power. The PD has then to provide Ethernet link within {{nowrap|5 seconds}} to the auto-negotiation mode switch port. A later CDP message with a type-length-value tells the PSE its final power requirement. A discontinued link pulses shuts down power.[47] In 2014, Cisco created another non-standard PoE implementation called Universal Power over Ethernet (UPOE). UPOE can use all 4 pairs, after negotiation, to supply up to 60 W.[48] Linear TechnologyA proprietary high-power development called LTPoE++ using a single CAT-5e Ethernet cable is capable of supplying varying levels at 38.7 W, 52.7 W, 70 W, and 90 W in addition to being backwards compatible with IEEE 802.3at.[49] MicrosemiPowerDsine, acquired by Microsemi in 2007, has been selling midspan power injectors since 1999 with its proprietary Power over LAN solution. Several companies such as Polycom, 3Com, Lucent and Nortel utilize PowerDsine's Power over LAN.[50]PassiveThe common 100 Mbit/s passive applications use the pinout of 802.3af mode B - with DC plus on pins 4 and 5 and DC minus on 7 and 8 (see chart below) and data on 1-2 and 3-6. Gigabit passive injectors use a transformer on the data pins to allow power and data to share the cable and is typically compatible with 802.3af Mode A. In the common "passive" PoE system, the injector does not communicate with the powered device to negotiate its voltage or wattage requirements, but merely supplies power at all times. Passive midspan injectors up to 12 ports simplify installations. Devices needing 5 Volts cannot typically use PoE at 5 V on Ethernet cable beyond short distances (about {{convert|15|ft|m}}) as the voltage drop of the cable becomes too significant, so a 24 V or 48 V to 5 V DC-DC converter is required at the remote end.[51] Passive PoE power sources are commonly used with a variety of indoor and outdoor wireless radio equipment, most commonly from Motorola (now Cambium), Ubiquiti, Mikrotik and others. Earlier versions of passive PoE 24VDC power sources shipped with 802.11a, 802.11g and 802.11n based radios are commonly 100 Mbit/s only. Specifications vary by manufacturer and model, but some of the common specifications include:{{cn|date=July 2018}}
Passive DC-to-DC injectors also exist which convert a 9 V to 36 V DC, or 36 V to 72 V DC power source to a stabilized 24 V 1 A, 48 V 0.5 A, or up to 48V 2.0A PoE feed with '+' on pins 4 & 5 and '−' on pins 7 & 8. These DC-to-DC PoE injectors are used in various telecom applications.[52] Power capacity limitsThe ISO/IEC TR 29125 and Cenelec EN 50174-99-1 draft standards outline the cable bundle temperature rise that can be expected from the use of 4PPoE. A distinction is made between two scenarios: 1.) bundles heating up from the inside to the outside, and 2.) bundles heating up from the outside to match the ambient temperature. The second scenario largely depends on the way that the cable bundle has been installed, whereas the first is solely influenced by the physical make-up of the cable. In a standard U/UTP cable, the PoE-related temperature rise increases by a factor of 5. In a shielded cable, this value drops to between 2.5 and 3, depending on the design. Put another way, the temperature increases by twice as much in a U/UTP cable bundle than in a comparable bundle of S/FTP cables. Pinouts
ReferencesExternal links
6 : Ethernet|Networking hardware|Network appliances|Electric power|IEEE standards|Power supplies |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||