词条 | Dental torque wrench |
释义 |
A dental torque wrench or restorative torque wrench is a torque wrench used to precisely apply a specific torque to a fastener bolt for fixation of an abutment, dentures or prostetics[1] on a dental implant.[2] Manual mechanical torque wrenchToggle torque wrenches (friction-style) and beam wrenches (spring-style) are the most common types in dentistry as manual mechanical torque-limiting devices.[3] Beam type wrenches in general are more consistent to its calibration than toggle types. The beam types with a dial indicator are the most precise to set the Tare torque (zero point reset). Because steam sterilization processes like an autoclave are applied to the dental torque wrenches and the length of time in use presents stress on the material, fatigue can occur.[4] Surgical motorThe surgical motor[5] is an electronic controlled torque-limiting device that also controls the speed. It is used with a twisted drill[6] to make space in the bone for the implant or to fasten the screw (torque control can be with a torque-limiting attachment) with a screwdriver bit. In high precision areas such as aerospace applications motor or pneumatic torque wrenches are set at a lower torque value after which the final torque is set with a manual mechanical torque wrench, they are calibrated before every use, if a wrench breaks or loses calibration every fastener done with that wrench is redone. CalibrationVarious studies point to deviations of 10% and higher than the desired torque, regular recalibration with a torque tester restores the required torque values.[7] Re-torquingAs the settling effect[8] (the flattening of the materials micro-surface under pressure) causes a lesser torque of around 10% in a relative short time re-torquing the fastener after 10 minutes reduces this effect[9] as the parts get more seated. Wet and dry torqueWet torques (bolts lubricated with saliva) have a higher mean torque than dry torques (unlubricated).[10] See also{{Portal|Dentistry}}
References1. ^{{Cite journal|pmid=23985429|year=2013|author1=Sella|first1=G. C.|title=Influence of different maintenance times of torque application on the removal torque values to loosen the prosthetic abutment screws of external hexagon implants|journal=Implant Dentistry|volume=22|issue=5|pages=534–9|last2=Lopes Pereira Neto|first2=A. R.|last3=Maziero Volpato|first3=C. A.|last4=De Vasconcellos|first4=D. K.|last5=Pekkan|first5=G|last6=Ozcan|first6=M|doi=10.1097/ID.0b013e31829e548d}} 2. ^{{Cite journal|pmid=23724209|pmc=3666070|year=2013|author1=Kazemi|first1=M|title=Evaluation of the accuracy and related factors of the mechanical torque-limiting device for dental implants|journal=Journal of Dentistry (Tehran, Iran)|volume=10|issue=2|pages=112–8|last2=Rohanian|first2=A|last3=Monzavi|first3=A|last4=Nazari|first4=M. S.}} 3. ^{{cite journal|last1=McCracken|first1=Michael S.|last2=Mitchell|first2=Lillian|last3=Hegde|first3=Rashmi|last4=Mavalli|first4=Mahendra D.|title=Variability of Mechanical Torque-Limiting Devices in Clinical Service at a US Dental School|journal=Journal of Prosthodontics|volume=19|issue=1|year=2010|pages=20–24|issn=1059-941X|doi=10.1111/j.1532-849X.2009.00524.x|pmid=19765196}} 4. ^{{cite journal|last1=Mir|first1=Maziar|title=The effect of steam sterilization on the accuracy of spring-style mechanical torque devices for dental implants|journal=Clinical, Cosmetic and Investigational Dentistry|volume=4|year=2012|pages=29–35|issn=1179-1357|doi=10.2147/CCIDEN.S32052|pmid=23674923|pmc=3652367}} 5. ^{{Cite journal|pmid=19587869|year=2009|author1=Neugebauer|first1=J|title=Comparison of torque measurements and clinical handling of various surgical motors|journal=The International Journal of Oral & Maxillofacial Implants|volume=24|issue=3|pages=469–76|last2=Scheer|first2=M|last3=Mischkowski|first3=R. A.|last4=An|first4=S. H.|last5=Karapetian|first5=V. E.|last6=Toutenburg|first6=H|last7=Zoeller|first7=J. E.}} 6. ^{{Cite journal|pmid=1769832|year=1991|author1=Nher|first1=H|title=The value of symptoms and clinical findings in cervical Chlamydia trachomatis infection|journal=Der Hautarzt; Zeitschrift für Dermatologie, Venerologie, und Verwandte Gebiete|volume=42|issue=11|pages=687–91|last2=Lamminger|first2=C|last3=Zimmermann|first3=J|last4=Petzoldt|first4=D}} 7. ^{{Cite journal|url=http://jdmt.mums.ac.ir/?_action=articleInfo&article=491|vauthors=Rajatihaghi H, Ghanbarzadeh J, Daneshsani N, Sahebalam R, Nakhaee M |title= The accuracy of various torque wrenches used in dental implant systems|journal= The Journal of Dental Materials and Techniques |year=2013|issue=2|volume=2|pages= 38–44}} 8. ^{{Cite journal|doi=10.1563/1548-1336(2003)029<0242:ISMATS>2.3.CO;2|pmid= 14620687|year= 2003|author1= Winkler|first1= S|title= Implant screw mechanics and the settling effect: Overview|journal= The Journal of Oral Implantology|volume= 29|issue= 5|pages= 242–5|last2= Ring|first2= K|last3= Ring|first3= J. D.|last4= Boberick|first4= K. G.}} 9. ^{{Cite journal|doi=10.1111/j.1600-0501.2010.02063.x|pmid= 21198900|year= 2011|author1= Kim|first1= K. S.|title= Variation in the total lengths of abutment/implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection|journal= Clinical Oral Implants Research|volume= 22|issue= 8|pages= 834–9|last2= Lim|first2= Y. J.|last3= Kim|first3= M. J.|last4= Kwon|first4= H. B.|last5= Yang|first5= J. H.|last6= Lee|first6= J. B.|last7= Yim|first7= S. H.}} 10. ^{{cite journal|last1=Nigro|first1=Frederico|last2=Sendyk|first2=Claudio L.|last3=Francischone Jr.|first3=Carlos Eduardo|last4=Francischone|first4=Carlos Eduardo|title=Removal torque of zirconia abutment screws under dry and wet conditions|journal=Brazilian Dental Journal|volume=21|issue=3|year=2010|pages=225–228|issn=0103-6440|doi=10.1590/S0103-64402010000300009|pmid=21203705}} 3 : Wrenches|Torque|Dental equipment |
随便看 |
|
开放百科全书收录14589846条英语、德语、日语等多语种百科知识,基本涵盖了大多数领域的百科知识,是一部内容自由、开放的电子版国际百科全书。