词条 | IBM FlashSystem | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
释义 |
| name = IBM FlashSystem | logo = | logo-size = | logo_caption = | image = RamSan-810.png | image-size = thumb | caption = Texas Memory Systems RamSan-810 flash storage system | invent-date = | invent-name = | conn1 = | via1_1 = | class-name = | class1 = | manuf1 = | designfirm = | manufacturer = IBM | introduced = April 11, 2013 | discontinued = | cost = | type = Enterprise computer data storage systems | processor = | frequency = | memory = | slots = | rom = | coprocessor = | connection = | ports = | power = | color = | dpi = | speed = | language = | weight = | dimensions = }}IBM FlashSystem products are enterprise computer data storage systems that store data on flash memory. Unlike storage systems that use standard solid-state drives, IBM FlashSystem products incorporate custom hardware based on technology from the 2012 IBM acquisition of Texas Memory Systems.[1] HistoryThe IBM FlashSystem architecture was originally developed by Texas Memory Systems (TMS) as their RamSan product line. TMS was a small private company founded in 1978 and based in Houston, Texas that supplied solid-state drive products to the market longer than any other company.[2] The TMS RamSan line of enterprise solid state storage products was first launched in the early 2000s,[3] and over seven RamSan technology generations were released through 2012, when TMS was acquired by IBM.[4] As RamSan technology evolved, TMS adapted the systems to different storage media (DRAM, single-level cell flash memory, and multi-level cell flash memory) and external storage area network interfaces (Fibre Channel and InfiniBand), but the core system design principles remained relatively constant: custom hardware with a shared internal network to maximize speed, particularly latency.[2] The last RamSan products available were the RamSan-710, RamSan-810, RamSan-720, and RamSan-820 systems, which were replaced directly with corresponding IBM FlashSystem products in 2013.[5] IBM FlashSystem products were first made generally available on April 11, 2013, in conjunction with the announcement of a US$1 billion investment in flash optimization research and development.[6] At the Flash Ahead event, IBM emphasized the economic "tipping point" that flash had reached versus traditional storage devices for high-performance applications.[7] On January 16, 2014, IBM announced the FlashSystem 840 product, which was the first FlashSystem designed entirely by IBM post-acquisition of TMS. The key enhancements of the new generation were RAS enhancements, higher capacities, higher performance, new 16 Gbit Fibre Channel and 10 Gbit Fibre Channel over Ethernet interfaces, and a new management GUI. IBM also announced the FlashSystem Enterprise Performance Solution, which added software features and functions to the 840, including real-time compression, replication, and snapshots.[8] TechnologyIBM FlashSystem products are based on a custom hardware architecture that incorporates field-programmable gate arrays (FPGAs). The FlashSystem design omits traditional server-based array controllers. The primary components of each FlashSystem unit include custom flash modules, external storage area network interfaces, and FPGA logic that spreads data through the system. Each flash module within a FlashSystem incorporates enterprise multi-level cell or single-level cell flash chips and FPGAs that provide IBM Variable Stripe RAID data protection as well as standard flash memory controller functions. IBM claims that these architectural attributes provide strong performance, reliability, and efficiency.[1] In August 2013, IBM submitted a single FlashSystem 820 SPC-1 benchmark result to the Storage Performance Council that showed fast response time (SPC-1 LRT) and high SPC-1 IOPS per external storage port - common measures of high storage performance - as well as low power consumption.[9] IBM claims that enterprise multi-level cell flash plus Variable Stripe RAID and other IBM reliability technology forms a good balance between reliability and economics for most enterprise environments. IBM Variable Stripe RAID is a patented[10] highly granular RAID 5 type data protection arrangement implemented across each set of 10 flash chips in the system. IBM FlashSystem 840, 820, and 720 products also include a second layer of RAID 5 implemented within the data distribution logic at the system level, providing "two-dimensional" data protection within the system. IBM claims that this two-dimensional protection is strongly differentiated within the industry.[11] Products
References1. ^1 {{Cite web |title= Flash or SSD: Why and When to Use IBM FlashSystem |last= Gilge |first= Megan |last2= Orlando |first2= Karen |url= http://www.redbooks.ibm.com/redpapers/pdfs/redp5020.pdf |publisher= IBM |date= June 26, 2013 |accessdate= January 3, 2014 }} 2. ^1 {{cite web |url=http://www.storagesearch.com/texasmem.html |title=Who's who in SSD? - Texas Memory Systems |last=Kerekes |first=Zsolt |publisher=ACSL |accessdate= January 3, 2014}} 3. ^{{cite press release |title= Texas Memory Systems Announces Availability of RAM-SAN 520 |publisher= Texas Memory Systems |date= January 8, 2001 |url= http://www.superssd.com/pressrelease/01082001.htm |archiveurl= https://web.archive.org/web/20011109205042/http://www.superssd.com/pressrelease/01082001.htm |archivedate= November 9, 2001 |accessdate= January 3, 2014 }} 4. ^{{cite press release |title= IBM Completes Acquisition of Texas Memory Systems |publisher= IBM | date= October 1, 2012 |url= http://www-03.ibm.com/press/us/en/pressrelease/38997.wss |accessdate= January 3, 2014 }} 5. ^{{cite news |last=Mellor |first=Chris |title=IBM pours $1 BEELLION into flash SSDs |work= The Register |date= April 15, 2013 |url= https://www.theregister.co.uk/2013/04/15/ibm_flashsystem/ |accessdate= January 3, 2014 }} 6. ^{{Cite web |title= IBM to Invest $1B in Flash Promotion |last= Handy |first= Jim |url= http://thessdguy.com/ibm-to-invest-1b-in-flash-promotion/ |publisher= Objective Analysis |date= April 15, 2013 |accessdate= January 3, 2014 }} 7. ^{{cite news |title= Big Blue's billion-dollar bet on SSD includes all-flash storage array |last=Lelii |first=Sonia |url= http://searchstorage.techtarget.com/news/2240181402/Big-Blues-billion-dollar-bet-on-SSD-includes-all-flash-storage-array |publisher= TechTarget |date= April 12, 2013 |accessdate= January 3, 2014 }} 8. ^{{cite web|title=IBM Introduces X6 Architecture, Optimizes x86-Based Servers for Cloud, Analytics|url=http://www-03.ibm.com/press/us/en/pressrelease/42796.wss|publisher=IBM|accessdate=23 January 2014}} 9. ^{{cite web |title= SPC Benchmark 1/Energy™ Executive Summary - IBM FlashSystem 820 (#AE00006) |url= http://www.storageperformance.org/benchmark_results_files/SPC-1E/IBM/AE00006_IBM_FlashSystem-820/ae00006_IBM_FlashSystem-820_SPC-1E_executive-summary.pdf |date= August 16, 2013 |publisher= Storage Performance Council |accessdate= January 3, 2014 }} 10. ^{{Citation |inventor1-last= Frost |inventor1-first= Holloway H. |inventor2-last= Camp |inventor2-first= Charles J. |title= FLASH-based memory system with static or variable length page stripes including data protection information and auxiliary protection stripes |issue-date= October 15, 2013 |patent-number= US8560881 B2 |country-code = US}} 11. ^{{cite web |url=https://www.ibm.com/developerworks/community/blogs/InsideSystemStorage/entry/enterprise_reliability_features_of_the_ibm_flashsystem?lang=en |title=Enterprise Reliability features of the IBM FlashSystem |last=Pearson |first=Tony |publisher=IBM developerWorks |date= November 22, 2013 |accessdate= January 3, 2014 }} External links
5 : Computer peripherals|IBM storage devices|Data storage|Solid-state computer storage|Solid-state computer storage media |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
随便看 |
|
开放百科全书收录14589846条英语、德语、日语等多语种百科知识,基本涵盖了大多数领域的百科知识,是一部内容自由、开放的电子版国际百科全书。