This article is about electronics. For the adjustment of engines for longer engine life see engine tuning. In electronics, derating (or de-rating) is the operation of a device at less than its rated maximum capability in order to prolong its life. Typical examples include operation below the maximum power rating, current rating, or voltage rating. In electronicsPower semiconductor devices have a maximum power dissipation rating usually quoted at a case temperature of {{convert|25|C|F}}. The datasheet for the device also includes a derating curve which indicates how much a device will dissipate without getting damaged at any given case temperature and this must be taken into account while designing a system. As can be seen from the derating curve image for a hypothetical bipolar junction transistor, the device (rated for 100 W at {{convert|25|C|F}}) cannot be expected to dissipate anything more than about 40 W if the ambient temperature is such that the temperature at which the device's case will stabilise (after heat-sinking) is {{convert|65|C|F}}. This final case temperature is a function of the thermal resistance between the device's case and the heat-sink; and the heat-sink and the ambient (this includes the heat-sink's temp/watt rating - with lower values implying better cooling characteristics). Some capacitors' voltage capability is reduced at higher temperatures because the softened dielectric (e.g., a polymer) is softened further by the heat and its breakdown field strength is reduced. Derating curves are included in data sheets for such capacitors. Derating can also be used to provide a safety margin for transient voltages or currents (spikes) that exceed normal operation, or simply to prolong life. For example the life of electrolytic capacitors is dramatically increased by operating them below their maximum temperature rating. In electrical installationsAll dimmers rely on heat conduction and convection to keep the electronic components cool. Similarly, power wiring (e.g., house wiring) not surrounded by an air space (e.g., inside a conduit) needs to have its current-limiting device (e.g. circuit breaker or fuse) adjusted so as not to carry as much current through that circuit. Derating is the reduction of the maximum capacity (load) a unit can reliably handle when fins/side sections are removed. See also{{Wiktionary|derate|derating|derated}}
References
1 : Electrical engineering |
随便看 |
|
开放百科全书收录14589846条英语、德语、日语等多语种百科知识,基本涵盖了大多数领域的百科知识,是一部内容自由、开放的电子版国际百科全书。