词条 | Flicker fusion threshold |
释义 |
The flicker fusion threshold, or flicker fusion rate, is a concept in the psychophysics of vision. It is defined as the frequency at which an intermittent light stimulus appears to be completely steady to the average human observer. Flicker fusion threshold is related to persistence of vision. Although flicker can be detected for many waveforms representing time-variant fluctuations of intensity, it is conventionally, and most easily, studied in terms of sinusoidal modulation of intensity. There are seven parameters that determine the ability to detect the flicker:
ExplanationAs long as the modulation frequency is kept above the fusion threshold, the perceived intensity can be changed by changing the relative periods of light and darkness. One can prolong the dark periods and thus darken the image; therefore the effective and average brightness are equal. This is known as the Talbot-Plateau law.[2] Like all psychophysical thresholds, the flicker fusion threshold is a statistical rather than an absolute quantity. There is a range of frequencies within which flicker sometimes will be seen and sometimes will not be seen, and the threshold is the frequency at which flicker is detected on 50% of trials. Different points in the visual system have very different critical flicker fusion rate (CFF) sensitivities; the overall threshold frequency for perception cannot exceed the slowest of these for a given modulation amplitude. Each cell type integrates signals differently. For example, rod photoreceptor cells, which are exquisitely sensitive and capable of single-photon detection, are very sluggish, with time constants in mammals of about 200 ms. Cones, in contrast, while having much lower intensity sensitivity, have much better time resolution than rods do. For both rod- and cone-mediated vision, the fusion frequency increases as a function of illumination intensity, until it reaches a plateau corresponding to the maximal time resolution for each type of vision. The maximal fusion frequency for rod-mediated vision reaches a plateau at about 15 Hz, whereas cones reach a plateau, observable only at very high illumination intensities, of about 60 Hz.[3][4] In addition to increasing with average illumination intensity, the fusion frequency also increases with the extent of modulation (the maximal relative decrease in light intensity presented); for each frequency and average illumination, there is a characteristic modulation threshold, below which the flicker cannot be detected, and for each modulation depth and average illumination, there is a characteristic frequency threshold. It should be noted that these values vary with the wavelength of illumination, because of the wavelength dependence of photoreceptor sensitivity, and they vary with the position of the illumination within the retina, because of the concentration of cones in central regions including the fovea and the macula, and the dominance of rods in the peripheral regions of the retina. The flicker fusion threshold is proportional to the amount of modulation; if brightness is constant, a brief flicker will manifest a much lower threshold frequency than a long flicker. The threshold also varies with brightness (it is higher for a brighter light source) and with location on the retina where the perceived image falls: the rod cells of the human eye have a faster response time than the cone cells, so flicker can be sensed in peripheral vision at higher frequencies than in foveal vision. This is essentially the concept known as the Ferry-Porter law, where it may take some increase in brightness, by powers of ten, to require as many as 60 flashes to achieve fusion, while for rods, it may take as little as four flashes, since in the former case each flash is easily cut off, and in the latter it lasts long enough, even after 1/4 second, to merely prolong it and not intensify it.[2] From a practical point of view, if a stimulus is flickering, such as computer monitor, decreasing the intensity level will eliminate the flicker.[5] The flicker fusion threshold also is lower for a fatigued observer. Decrease in the critical fusion frequency has often been used as an index of central fatigue.[6] Technological considerationsDisplay frame rateFlicker fusion is important in all technologies for presenting moving images, nearly all of which depend on presenting a rapid succession of static images (e.g. the frames in a cinema film, TV show, or a digital video file). If the frame rate falls below the flicker fusion threshold for the given viewing conditions, flicker will be apparent to the observer, and movements of objects on the film will appear jerky. For the purposes of presenting moving images, the human flicker fusion threshold is usually taken between 60 and 90 hertz (Hz), though in certain cases it can be higher by an order of magnitude.[7] In practice, movies are recorded at 24 frames per second and displayed by repeating each frame two or three times for a flicker of 48 or 72 Hz. Standard-definition television operates at 25 or 30 frames per second, or sometimes at 50 or 60 (half-)frames per second through interlacing. High-definition video is displayed at 24, 25, 30, 60 frames per second or higher. Display refresh rateCRT displays usually by default operated at a vertical scan rate of 60 Hz, which often resulted in noticeable flicker. Many systems allowed increasing the rate to higher values such as 72, 75 or 100 Hz to avoid this problem. Most people do not detect flicker above 400 Hz.[8]{{irrelevant citation|date=January 2018|reason=Citation does not address humans at all, it is about Tritonia, a gastropod.}} Other display technologies do not flicker noticeably, so the frame rate is less important. LCD flat panels do not seem to flicker at all, as the backlight of the screen operates at a very high frequency of nearly 200 Hz, and each pixel is changed on a scan rather than briefly turning on and then off as in CRT displays. However, the nature of the back-lighting used can induce flicker – LEDs cannot be easily dimmed, and therefore use pulse-width modulation to create the illusion of dimming, and the frequency used can be perceived as flicker by sensitive users.[9][10][11] LightingFlicker is also important in the field of domestic (alternating current) lighting, where noticeable flicker can be caused by varying electrical loads, and hence can be very disturbing to electric utility customers. Most electricity providers have maximum flicker limits that they try to meet for domestic customers. Fluorescent lamps using conventional magnetic ballasts flicker at twice the supply frequency. Electronic ballasts do not produce light flicker since the phosphor persistence is longer than a half cycle of the higher operation frequency of 20 kHz. The 100–120 Hz flicker produced by magnetic ballasts is associated with headaches and eyestrain.[12]Individuals with high critical flicker fusion threshold are particularly affected by light from fluorescent fixtures that have magnetic ballasts: their EEG alpha waves are markedly attenuated and they perform office tasks with greater speed and decreased accuracy. The problems are not observed with electronic ballasts.[13] Ordinary people have better reading performance using high-frequency (20–60 kHz) electronic ballasts than magnetic ballasts,[14] although the effect was small except at high contrast ratio. The flicker of fluorescent lamps, even with magnetic ballasts, is so rapid that it is unlikely to present a hazard to individuals with epilepsy.[15] Early studies suspected a relationship between the flickering of fluorescent lamps with magnetic ballasts and repetitive movement in autistic children.[16] However, these studies had interpretive problems[17] and have not been replicated. LED lamps generally do not benefit from flicker attenuation through phosphor persistence, the notable exception being white LEDs. Flicker at frequencies as high as 2 kHz can be perceived by humans during saccades[18] and frequencies above 3 kHz have been recommended to avoid human biological effects.[19] Visual phenomenaIn some cases, it is possible to see flicker at rates beyond 2000hz (2khz) in the case of high-speed eye movements (saccades) or object motion, via the "phantom array" effect.[20][21] Fast-moving flickering objects zooming across view (either by object motion, or by eye motion such as rolling eyes), can cause a dotted or multicolored blur instead of a continuous blur, as if they were multiple objects.[22] Stroboscopes are sometimes used to induce this effect intentionally. Some special effects, such as certain kinds of electronic glowsticks commonly seen at outdoor events, have the appearance of a solid color when motionless but produce a multicolored or dotted blur when waved about in motion. These are typically LED-based glow sticks. The variation of the duty cycle upon the LED(s), results in usage of less power while by the properties of flicker fusion having the direct effect of varying the brightness.{{Citation needed|date=April 2009}} When moved, if the frequency of duty cycle of the driven LED(s) is below the flicker fusion threshold timing differences between the on/off state of the LED(s) becomes evident, and the color(s) appear as evenly spaced points in the peripheral vision. A related phenomenon is the DLP rainbow effect, where different colors are displayed in different places on the screen for the same object due to fast motion. FlickerFlicker is the perception of visual fluctuations in intensity and unsteadiness in the presence of a light stimulus, that is seen by a static observer within a static environment. Flicker that is visible to the human eye will operate at a frequency of up to 80 Hz. [23] Stroboscopic effectThe stroboscopic effect is sometimes used to "stop motion" or to study small differences in repetitive motions. The stroboscopic effect refers to the phenomenon that occurs when there is a change in perception of motion, caused by a light stimulus that is seen by a static observer within a dynamic environment. The stroboscopic effect will typically occur within a frequency range between 80 and 2000 Hz. [24] Phantom arrayPhantom array, also known as the ghosting effect, occurs when there is a change in perception of shapes and spatial positions of objects. The phenomenon is caused by a light stimulus in combination with rapid eye movements (saccades) of an observer in a static environment. Similar to the stroboscopic effect, the phantom effect will also occur between 80 and 2000 Hz. [25] Non-human speciesThe flicker fusion threshold also varies between species. Pigeons have been shown to have higher threshold than humans (100 Hz vs. 60 Hz), and the same is probably true for all birds, particularly birds of prey.[26] Many mammals have a higher proportion of rods in their retina than humans do, and it is likely that they would also have higher flicker fusion thresholds. This has been confirmed in dogs.[27] Research also shows that size and metabolic rate are two factors that come into play: small animals with high metabolic rate tend to have high flicker fusion thresholds.[28][29] See also
References1. ^S.W. Davis, Auditory and Visual Flicker-Fusion as Measures of Fatigue, The American Journal of Psychology, Vol. 68. No. 4. Dec., 1955 {{refbegin}}2. ^1 "eye, human."Encyclopædia Britannica. 2008. Encyclopædia Britannica 2006 Ultimate Reference Suite DVD 3. ^INTERMITTENT STIMULATION BY LIGHT : V. THE RELATION BETWEEN INTENSITY AND CRITICAL FREQUENCY FOR DIFFERENT PARTS OF THE SPECTRUM. Hecht S, Shlaer S. J Gen Physiol. 1936 Jul 20;19(6):965–77. 4. ^{{cite web|url=http://www.bio.net/bionet/mm/neur-sci/2007-July/061925.html |title=[Neuroscience] Re: Flicker Fusion Threshold Examples |publisher=Bio.net |date= |accessdate=2013-05-05}} 5. ^{{cite web|url=http://webvision.med.utah.edu/temporal.html |title=Temporal Resolution – Webvision |publisher=Webvision.med.utah.edu |date=2011-03-30 |accessdate=2013-05-05}} 6. ^Ernst Simonson and Norbert Enzer, Measurement of fusion frequency of flicker as a test for fatigue of the central nervous system, J. Indus. Hyg. Tox., 23, 1941, 83–89. 7. ^{{citation|pmc=4314649|title=Humans perceive flicker artefacts at 500 Hz|author=James Davis|year=1986|pmid=25644611|doi=10.1038/srep07861|volume=5|journal=Sci Rep|pages=7861}} 8. ^{{cite journal|last1=Chase|first1=Ronald|title=The Initiation and Conduction of Action Potentials in the Optic Nerve of Tritonia|journal=Journal of Experimental Biology|date=1974|volume=60|pages=721–734|url=http://jeb.biologists.org/content/60/3/721}} 9. ^{{cite web|url=http://crispycromar.com/psa-led-backlighting-can-cause-migraine-headaches/ |title=PSA: LED-Backlighting Can Cause Migraine Headaches |publisher=CrispyCromar.com |date= |accessdate=2013-05-05}} 10. ^{{cite web|author=View: Everyone Only Notes |url=https://discussions.apple.com/thread/1677617?threadID=1677617&tstart=0 |title=Eye strain from LED backlighting in...: Apple Support Communities |publisher=Discussions.apple.com |date=2008-08-23 |accessdate=2013-05-05}} 11. ^{{cite web|author=Wilkins, Veitch & Lehman|url=http://www.essex.ac.uk/psychology/overlays/2010-195.pdf |title=LED Lighting Flicker and Potential Health Concerns: IEEE Standard PAR1789 Update |publisher=University of Essex, UK |date=2010 |accessdate=2014-07-01}} 12. ^ {{cite web | title = Full-spectrum Fluorescent lighting : A review of its effects on physiology and health | url = http://journals.cambridge.org/action/displayAbstract?fromPage=online&aid=81689 | accessdate = 2008-04-23 }} 13. ^{{cite journal |journal= Ergonomics |volume=41 |issue=4 |pages=433–47 |year=1998 |title= The impact of flicker from fluorescent lighting on well-being, performance and physiological arousal |vauthors=Küller R, Laike T |doi= 10.1080/001401398186928 |pmid= 9557586}} 14. ^{{cite journal |journal= Light Res Tech |volume=27 |issue=4 |year=1995 |pages=243–256 |url=http://www.nrc-cnrc.gc.ca/obj/irc/doc/pubs/nrcc38944/nrcc38944.pdf |accessdate=2012-06-28 |vauthors=Veitch JA, McColl SL |title= Modulation of fluorescent light: flicker rate and light source effects on visual performance and visual comfort |doi= 10.1177/14771535950270040301}} 15. ^{{cite journal |journal=Epilepsia |year=1979 |volume=20 |issue=6 |pages=725–7 |title= Fluorescent lighting and epilepsy |vauthors=Binnie CD, de Korte RA, Wisman T |pmid=499117 |doi=10.1111/j.1528-1157.1979.tb04856.x}} 16. ^{{cite journal |journal= J Autism Child Schizophr |year=1976 |volume=6 |issue=2 |pages=157–62 |title= The effects of fluorescent and incandescent illumination upon repetitive behaviors in autistic children |vauthors=Colman RS, Frankel F, Ritvo E, Freeman BJ |doi=10.1007/BF01538059 |pmid=989489}} 17. ^{{cite journal |journal= J Child Psychol Psychiatry |year=1999 |volume=40 |issue=6 |pages=839–49 |title= Annotation: Repetitive behaviour in autism: a review of psychological research |author= Turner M |pmid=10509879 |doi= 10.1017/S0021963099004278}} 18. ^{{cite journal|vauthors=Roberts JE, Wilkins AJ|title=Flicker can be perceived during saccades at frequencies in excess of 1 kHz|journal=Lighting Research & Technology|volume=45|number=1|pages=124–132|year=2013|doi=10.1177/1477153512436367}} 19. ^{{cite journal|vauthors=Lehman B, Wilkins AJ|volume=2014|number=09|pages=18–26|title=Designing to Mitigate Effects of Flicker in LED Lighting: Reducing risks to health and safety|journal=IEEE Power Electronics Magazine|doi=10.1109/MPEL.2014.2330442|year=2014}} 20. ^http://www.energy.ca.gov/appliances/2014-AAER-01/prerulemaking/documents/2014-09-29_workshop/comments/Professor_Arnold_J_Watkins_Comments_2014-11-25_TN-74074.pdf 21. ^http://opensiuc.lib.siu.edu/cgi/viewcontent.cgi?article=1538&context=tpr 22. ^http://www.thenakedscientists.com/forum/index.php?topic=45126.0 |A visually accurate description of the ghosting/ phantom array effect 23. ^{{cite web|author= |url=https://unios.com/wp-content/uploads/2019/02/UN_Driving-the-Flicker-Free-Effect_White-Paper-190205.pdf |title=Driving the Flicker-Free Effect |publisher=Unios|date=2019-02-05|accessdate=2019-02-08 | location=Perth}} 24. ^{{cite web|author= |url=https://unios.com/wp-content/uploads/2019/02/UN_Driving-the-Flicker-Free-Effect_White-Paper-190205.pdf |title=Driving the Flicker-Free Effect |publisher=Unios|date=2019-02-05|accessdate=2019-02-08 | location=Perth}} 25. ^{{cite web|author= |url=https://unios.com/wp-content/uploads/2019/02/UN_Driving-the-Flicker-Free-Effect_White-Paper-190205.pdf |title=Driving the Flicker-Free Effect |publisher=Unios|date=2019-02-05|accessdate=2019-02-08 | location=Perth}} 26. ^{{Harv|Winkler|2005}} 27. ^{{cite web|author= |url=http://onpoint.wbur.org/2009/09/22/a-dogs-eye-view |title=A Dog's Eye View | On Point with Tom Ashbrook |publisher=Onpoint.wbur.org |date= |accessdate=2013-05-05 |deadurl=yes |archiveurl=https://web.archive.org/web/20131020162644/http://onpoint.wbur.org/2009/09/22/a-dogs-eye-view |archivedate=October 20, 2013 }} 28. ^{{cite news|author1=Kevin Healy |author2=Luke McNally |author3=Graeme D. Ruxton |author4=Natalie Cooper |author5=Andrew L. Jackson |title=Metabolic rate and body size linked with perception of temporal information |publisher=Elsevier|date= 2013-10-01|doi=10.1016/j.anbehav.2013.06.018 }} 29. ^{{cite news|author=The Economist |url=https://www.economist.com/news/science-and-technology/21586532-small-creatures-fast-metabolisms-see-world-action-replay-slo-mo |title=Slo-mo mojo: How animals perceive time |publisher=Economist|date= 2013-09-21|accessdate=2013-10-20 | location=London}}
| last = Winkler | first = Robert | title = The Need for Speed | work = The New York Times | date = 2005-11-13 | url = https://www.nytimes.com/2005/11/13/opinion/nyregionopinions/13WEwinkler.html }}
| title = The Flicker Fusion Factor: Why we can't drive safely at high speed | first = Robert | last = Winkler | url = http://pages.cthome.net/rwinkler/fff.htm | archiveurl = https://web.archive.org/web/20101205102051/http://pages.cthome.net/rwinkler/fff.htm | archivedate = 2010-12-05 | postscript =, repost on author's personal website. }}
External links
1 : Vision |
随便看 |
|
开放百科全书收录14589846条英语、德语、日语等多语种百科知识,基本涵盖了大多数领域的百科知识,是一部内容自由、开放的电子版国际百科全书。