词条 | Talcher–Kolar HVDC system | ||||||||
释义 |
| name = Talcher–Kolar HVDC system | photo = | caption = | map = | map_caption = Location of Talcher–Kolar HVDC system | country = India | state = Odisha, Karnataka | province = | coordinates = {{Coord|21|06|01|N|85|03|49|E|type:landmark|name= Talcher–Kolar HVDC system – Talcher converter station}} {{Coord|13|10|39|N|78|07|00|E|type:landmark|name= Talcher–Kolar HVDC system – Kolar converter station }} | lat = | long = | direction = | start = Talcher, Odisha (Eastern Region) | through = | finish = Kolar, near Bangalore (Southern Region) | par = | owner = Power Grid Corporation of India | partners = | operator = | cable_manufacturer = | cable_installer = | cable_layer = | substation_manufacturer= | substation_installer= Siemens | contractors = | construction = | expected = | est = 2003 | decom = | type = Transmission | current_type = HVDC | length_km = 1450 | capacity = 2000 MW | AC_voltage = | DC_voltage = ±500 kV | poles_no = 2 | circuits_no = }} The Talcher–Kolar HVDC system, otherwise known as the East–South interconnection II is a 1450 km HVDC transmission connection between the eastern and southern regions in India connecting four states namely Odisha, Andhra Pradesh, Tamil Nadu and Karnataka. The system has a transmission voltage of ±500 kV and was originally put into service in March 2003,[1] with a rated power of 2000 MW. In 2007 the scheme was upgraded to 2500 MW. The Talcher–Kolar HVDC system is owned by Power Grid Corporation of India and the converter stations were built by Siemens. The scheme is a conventional bipolar system with overhead lines for the high-voltage conductors and ground return for the neutral current. Ground electrodesThe scheme includes two ground electrodes, of ring construction, located at Rohila, 28.5 km northeast of the Talcher converter station and at Chikkadasarahalli, 30 km northwest of the Kolar converter station.[1] However, the soil conditions at some distance from the electrode at Chikkadasarahalli were later found to have higher than expected soil resistivity. These geological effects gave rise to problems with DC currents flowing into the neutral connections of transformers at nearby AC substations, which required the addition of DC blocking devices. Sites
References1. ^1 Nayak R.N., Sasmal R.P., Sen S., Pelly B., Riedel P., Experience with blocking devices during monopolar operation of +/- 500kV, 2000MW Talcher–Kolar HVDC system in India, CIGRÉ session, Paris, 2006, paper reference B4-204. External links{{GeoGroupTemplate}}
6 : 2003 establishments in India|HVDC transmission lines|Electric power transmission infrastructure in India|Converter stations|Energy in Odisha|Energy infrastructure completed in 2003 |
||||||||
随便看 |
|
开放百科全书收录14589846条英语、德语、日语等多语种百科知识,基本涵盖了大多数领域的百科知识,是一部内容自由、开放的电子版国际百科全书。