name= LM6000image= General Electric LM6000.jpgcaption= LM6000 GTG in an electrical power plant application
}}{{Infobox Aircraft Engine
type= Gas turbinenational origin = United Statesmanufacturer= General Electricfirst run=major applications=number built =program cost =unit cost =developed from = General Electric CF6developed into =variants with their own articles =
}}

The General Electric LM6000 is a turboshaft gas turbine. The LM6000 is derived from the CF6-80C2 aircraft turbofan. It has additions and modifications designed to make it more suitable for marine propulsion, industrial power generation, and marine power generation use. These include an expanded turbine section to convert thrust into shaft power, supports and struts for mounting on a steel or concrete deck, and reworked controls packages for power generation. It has found wide use including peaking power plants, fast ferries and high speed cargo ship applications.

Design and development

The LM6000 provides 54,610 shaft horsepower (40,700 kW) from either end of the low-pressure rotor system, which rotates at 3,600 rpm. This twin spool design with the low pressure turbine operating at 60 Hz, the dominant electrical frequency in North America, eliminates the need for a conventional power turbine. Its high efficiency and installation flexibility make it ideal also for a wide variety of utility power generation and industrial applications, especially peaker and cogeneration plants.

GE has several option packages for industrial LM6000s, including SPRINT (Spray Inter-Cooled Turbine), water injection (widely known as "NOx water"), STIG (Steam Injected Gas Turbine) technology and DLE (Dry Low Emissions) which utilizes a combustor with premixers to maximize combustion efficiency. The SPRINT option is designed to increase efficiency and power of the turbine, while the water injection, STIG and DLE are for reducing emissions. An alternative form of power augmentation is Evaporative Cooling, which is a water fogging system that sprays a fine mist of water into the inlet air before the air filters. This system is high maintenance and may be replaced by chillers in newer units. The SPRINT system injects demineralized water into the engine either upstream of the low pressure compressor or between the low pressure and high pressure compressors. The water injection system injects water into the primary or secondary fuel nozzle inputs, usually on natural gas fired engines.

The GE LM6000 PC is rated to provide more than 43 MW with a thermal efficiency of around 42% LHV[1] at ISO conditions. With options, this can be increased to around 50 MW rated power.[2]

Applications

Over 1000 LM6000 gas turbines shipped and over 21 million hours of operation. Applications include power generation for combined cycle or peak power. Other applications include combined heat & power for industrial & independent power producers.

Typical users:

  • Hospitals
  • Airports
  • Pulp and paper, cement, mining plants
  • Gas pipelines, refineries, gas production
  • Utilities
  • Cruise ships and fast ferries

See also

{{aircontent
|related=
  • General Electric CF6
  • General Electric LM2500
  • General Electric LMS100

|similar engines=
|lists=
  • List of aircraft engines

|see also=
}}

References

1. ^GE LM6000 product brochure {{webarchive|url=https://web.archive.org/web/20150905141815/http://www.geaviation.com/engines/docs/marine/datasheet-lm6000.pdf |date=2015-09-05 }}
2. ^GE LM6000 page

External links

{{Commons}}
  • GE LM6000 website
{{GE aeroengines}}{{Aero-derivative engines}}

3 : Aero-derivative engines|Marine engines|Gas turbines